lower speed.
3. Pilot holes
When drilling a large hole in tough material
(i.e. steel), we recommend drilling a small
pilot hole first before using a large drill bit.
4. Drilling tiles
Select the drill/impact action selector switch
to the "drill symbol" position to drill the tile.
When tile has been penetrated, switch over to
"hammer symbol" position.
5. cool the motor
If your power tool becomes too hot, set the
speed to maximum and run no load for 2-3
minutes to cool the motor.

MAINTENANCE

Remove the plug from the socket before
carrying out any adjustment, servicing or
maintenance.
Your power tool requires no additional
lubrication or maintenance.
There are no user serviceable parts in your
power tool. Never use water or chemical
cleaners to clean your power tool. Wipe clean
with a dry cloth. Always store your power tool
in a dry place. Keep the motor ventilation slots
clean. Keep all working controls free of dust.
Occasionally you may see sparks through the
ventilation slots. This is normal and will not
damage your power tool.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order to
avoid a hazard.

TROUBLESHOOTING

1. If your power tool does not start, check the
plug on the power supply first.
2. If the drill doesn't work properly, check the
drill bit for sharpness, replace drill bit if worn.
Check that the drill is set to forward rotation
for normal use.
3. If a fault can not be rectified, return the tool
to an authorized dealer for repair.
Impact drill
ENVIRONMENTAL
PROTECTION
Waste electrical products should not
be disposed of with household waste.
Please recycle where facilities exist.
Check with your local authorities or retailer for
recycling advice.
PLUG REPLACEMENT
(UK & IRELAND ONLY)
If you need to replace the fitted plug then
follow the instructions below.
ImPORTaNT
The wires in the mains lead are colored in
accordance with the following code:
BLuE = NEuTRaL
Brown = Live
As the colors of the wires in the mains lead of
this appliance may not correspond with the
colored markings identifying the terminals
in your plug, proceed as follows. The wire
which is colored blue must be connected to
the terminal which is marked with N. The wire
which is colored brown must be connected to
the terminal which is marked with L.
WaRNINg: Never connect live or neutral
wires to the earth terminal of the plug. Only
fit an approved 13ABS1363/A plug and the
correct rated fuse.
NOTE: If a moulded plug is fitted and has to
be removed take great care in disposing of the
plug and severed cable, it must be destroyed
to prevent engaging into a socket.
Connect
Blue to N
(neutral)
Outer sleeve
firmly clamped
13 Amp fuse approved
to BS1362
Brown L (live)
Cable grip
EN