Analog Output
Nominal Range (V)
Positive Full
Negative Full
Scale
10.0
Note: Accuracies are valid for analog output following an internal calibration. Analog output accuracies are listed for
operation temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or factory calibration
temperature. Temp Drift applies only if ambient is greater than ±10 °C of previous external calibration.
© National Instruments Corporation
Settling time
Step Size
±20.0 V
±2.0 V
±0.2 V
Crosstalk................................................. –80 dB, DC to 100 kHz
Output Characteristics
Number of channels ............................... 8 single-ended, voltage output
Resolution .............................................. 16 bits, 1 in 65,536
Update time ............................................ 1.0 µs
Max update rate...................................... 1 MS/s
Type of DAC.......................................... Enhanced R-2R
Data transfers ......................................... Interrupts, programmed I/O
Accuracy Information
% of Reading
Scale
24 Hours
–10.0
0.0335
Accuracy
16 LSB
4 LSB
µ
7.5
s
10.3
µ
2.7
s
4.1
µ
1.7
s
2.9
Absolute Accuracy
µ
1 Year
Offset (
V)
0.0351
2366
A-3
Appendix A
Specifications
2 LSB
µ
µ
s
40
s
µ
µ
s
5.1
s
µ
µ
s
3.6
s
Absolute
Accuracy at
Temp Drift
Full Scale
(%/ °C)
(mV)
0.0005
5.88