Step 8 Wiring The Fireplace - Heat-N-Glo 6000CAMP Installer's Manual

Table of Contents

Advertisement

3/16" PIGGYBACK CONNECTOR
GAS VALUE
THERMOCOUPLE
Figure 36. Standing Pilot Ignition Wiring Diagram
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS TO PREVENT
ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC to operate.
WARNING: DO NOT CONNECT 110-120 VAC
!
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.
VARIABLE SPEED CONTROL
BLK
BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
Figure 37. Fan Wiring Diagram
WHITE T2
RED T1
THERMOPILE
BLACK S1
JUNCTION BOX
BLK
BLK
BLK
WHT
WHT
BLK
GROUND
GRN
BLK
WHT
110-120 VAC
BLACK S2
ON
OFF
ON/OFF
SWITCH
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
WARNING: DO NOT CONNECT 110-120 VAC
!
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCON-
NECTION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.
O
BLOWER RECEPTACLE
BLOWER
JUNCTION BOX
FAN
28
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)