Heat-N-Glo 6000CAMP Installer's Manual page 13

Table of Contents

Advertisement

VENTING WITH ONE (1) 90° ELBOW
V
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
V+H=40' MAX. (12.4m)
NOTE: There MUST be a 25% reduction in total H
when using flex vent except when using the
simple up and out installation (see Figure 6).
NOTE: On vertical venting configurations where
the vertical component is over 10 feet, you may
want to install the vertical baffle included in the
manual bag assembly to improve flame
appearance.
Figure 12. Venting with One 90° Elbow
VENTING WITH ONE (1) 90° ELBOW
V (FT.)
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
V+H= 40' MAX. (12.4MM) H = 20' MAX. (6.2m)
H
Figure 13. Venting with One 90° Elbow
H
2' MAX. (610mm)
4' MAX. (1.22m)
6' MAX. (1.86m)
8' MAX. (2.4m)
H = 8' MAX. (2.4m)
H (FT.)
5' MAX. (1.52m)
10' MAX. (3.1m)
15' MAX. (4.65m)
20' MAX. (6.2m)
NOTE: There MUST be a 25% reduction in
total H when using flex vent except when
V
using the simple up and out installation
(see Figure 6).
NOTE: For corner installations: A 6-inch (152mm)
section of straight pipe may need to be attached to
the fireplace before a 90
pipe to clear the top standoffs.
NOTE: If a 90
o
elbow is first attached to the unit,
the maximum horizontal run is 3-feet (914mm).
15
o
elbow, to allow the vent