120 VAC
JUNCTION BOX
REM
FAN
TRANSFORMER
REMOTE
RECEIVER
RED
ON/OFF
SWITCH
ASSEMBLY
Figure 26. Intermittent Pilot Ignition (IPI) Wiring Diagram
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS BY UN-
PLUGGING FROM THE JUNCTION BOX IF ABSENT FOR
EXTENDED TIME PERIODS. THIS WILL PREVENT AC-
CIDENTAL FIREPLACE OPERATION.
For Intermittent Pilot Ignition (IPI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.
NOTE: Remove twist-tie from male cord to remote receiver
and plug into electric box terminal marked "remote". Fe-
male cord is used if fan kit is to be installed.
3V
BATTERY
BACKUP
RED
BROWN
BROWN
ORANGE
ORANGE
BLACK (IGNITOR)
I
S
BLACK (SENSOR)
IGNITION
MODULE
3V
GROUND TO
FIREPLACE
CHASSIS
BLACK
Remove transformer from shipping position by cutting and
removing cable tie.
Plug transformer into electric box terminal marked "fan".
Check that antenna wire is held in place by two clips on the
lower flange (see Figure 35).
Optional Fan Kits
Fan kits can be installed by plugging into cord from remote
receiver. (The fan will have three speeds controlled by the
remote and will not use the rheostat or temperature control
provided with the fan kit).
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
22
ORANGE
DEXEN
VALVE
GREEN
SOLENOID
SPARK TO
PILOT IGNITOR
PILOT ASSEMBLY
AND VALVE
ASSEMBLY
MUST BE
GROUNDED
(COMMON GROUND
WITH FIREPLACE
CHASSIS)