A zone is an input to the DS7060 Control
Communicator. There are 6 hard-wired zones on the
main circuit board.
• Disabled: These zones are not monitored, and will
not generate alarm or trouble conditions.
• Perimeter Instant: These zones arm and disarm
with the panel, and never have entry or exit delays.
Violation of this type of zone will cause an intrusion
alarm.
• 24-Hour Auxiliary: This zone type will cause an
auxiliary alarm. It is always active. An alarm on a
24-hour zone (fire or aux.) will be silenced by
entering a disarm code whether the control is
armed or not. If the 24-hour zone restores and
alarms again the alarm will sound again. 24-hour
zones may generate trouble conditions during
armed or disarmed periods. All 24-hour zones that
have alarmed and are not restored will show as
"Not Ready." They will prevent arming unless the
panel is force armed. 24-hour zones that have been
bypassed manually will remain so until manually
unbypassed, even if the control is armed and
disarmed. Bypasses of these zones will be
displayed on the keypad.
Page 6
• Interior Follower: This zone is not active when the
• Interior Home/Away: This zone becomes interior
• Interior Instant: These zones arm and disarm with
• Perimeter Homeguard: This zone type is active
• Perimeter Follower Homeguard: These zones
Copyright © 1997-98 Detection Systems, Inc.
Perimeter Delayed: These zones have entry or
exit delays unless the panel is armed in the "No
Entry" mode. In the "No Entry" mode, the exit delay
is in effect immediately after entering the "No Entry"
mode, but is disabled upon expiration of the exit
delay.
A delayed zone is ignored during the programmed
times immediately following arming during the exit
delay. If the zone is faulted while the control is
armed and not in exit delay then an entry delay
cycle will be started, and a continuous entry tone
will be sounded at the keypads. If the control is not
disarmed by the end of the entry delay, an alarm
will result. There are no keypad tones during the
exit delay unless the feature "Keypad Audible
During Exit Delay" is selected. Refer to Section 6.9,
Address 09. If an entry delay is running and another
entry delay zone is faulted, the entry delay timer is
unaffected and will continue timing from the first
entry. The entry delay time and exit delay time can
be set independently.
If a delayed zone remains faulted at the end of an
exit delay, the panel will optionally signal an exit
error condition. The entry delay will be begin as
above, and the alarm output will activate with the
pattern selected for that zone. If the control is not
disarmed by the end of the entry delay, an alarm
will result, and an exit error report will be sent to the
central station (following the alarm report if
programmed). The alarm output will deactivate. If
the control is disarmed during the delay period
started by the exit error condition, no reports will be
sent to the central station and any outputs on during
the exit error will deactivate. The exit error report
does not follow the dialer delay option.
panel is disarmed, or is armed in the perimeter only
mode. When the zone is active, if a delayed zone is
violated first, this zone is also delayed. If an instant
zone or this zone type is violated first, this zone is
not delayed. This zone is not active during the exit
delay.
instant if the system is armed and an entry/exit
delay zone is violated during the exit delay time. If
the system is armed and an entry/exit zone is not
violated, these zones will be bypassed. These
zones are bypassed if armed perimeter only.
the panel. They are not active if the panel is armed
in the "perimeter only" mode. They never have entry
or exit delays. Violation of this type of zone will
cause an intrusion alarm.
when the panel is armed. When the panel is armed
perimeter only, this is a delayed zone. When armed
full, this is an instant zone.
are always delayed when the panel is armed in the
perimeter only mode. When the panel is fully
DS7060-AUS Reference Guide