Download Print this page

Bosch DS7060 Reference Manual page 5

Hide thumbs Also See for DS7060:

Advertisement

4/98
2SHUDWLQJ*XLGH
 8QGHUVWDQGLQJ WKH '6 '6 DQG '6 .H\SDGV
• The DS7443 is a 6 zone LED keypad; its LEDs represent the zones of the system.
• The DS7445 is an 8 zone LED keypad; its LEDs represent the zones of the system (LEDs for zones 7 and 8 are
not used).
• The DS7447 is an alpha-numeric LCD keypad.
All three keypads display information on various control panel functions. A built-in sounder is used to annunciate
keystroke entries and as an interior warning device.
Volume Control (DS7445 and DS7447 only): The keypad sounder volume can be adjusted using the [1] and [4]
keys along with the [*] key. Hold the [*] key while pressing the [1] key to increase the volume or the [4] key to
decrease the volume. The volume adjustment does not affect the volume during an alarm.
Backlight Control (DS7447 only): The display backlight intensity can be adjusted using the [3] and [6] keys along
with the [*] key. Hold the [*] while pressing the [3] key to increase brightness or the [6] key to decrease brightness.
NOTE: After the backlight and volume are adjusted, you must arm then disarm the system once to store this
information in the control panel. If power is disconnected before the panel is armed, the backlight and
volume levels return to the default settings.
DS7447 KEYPAD
This chart will help you understand what each Light/LED represents.
LIGHT
Armed
The control panel is disarmed.
(red)
One or more zones are not ready
Status
to arm.
(green)
Power
The control panel has lost power.
No AC for battery.
(green)
There are no fire alarms.
Fire
(red)
The perimeter is not armed.
Perimeter*
(yellow)
Supervisory*
This light will not be sued by the
DS7060.
(yellow)
The bells do not need to be or
Bell Silenced*
have not been silenced.
(yellow)
Trouble*
There are no trouble conditions.
(yellow)
Zone LEDs**
There are no zone alarms.
(red)
* = This light is present on the DS7445 only.
Page 5
DS7443 KEYPAD
OFF
An exit delay is in progress or an
alarm has occurred.
One or more zones are bypassed.
Control panel problems. Refer to
Error displays.
A fire zone is in alarm.
This light will not flash.
Not used.
This light will not flash.
This light will not flash.
A zone (1-6) is in alarm.
Copyright © 1997-98 Detection Systems, Inc.
DS7445 KEYPAD
FLASHING
The control panel is armed and no
alarms have occurred.
All zones are ready to arm.
Normal operation.
A fire trouble condition exists.
The perimeter is armed.
Not used.
The bells have been silenced. To
clear, enter the Fire Reset command.
A trouble condition exists.
A zone (1-6) is not ready to arm or if
a fire zone, a trouble condition exists.
** = This light is present on the DS7443 and DS7445.
ON
DS7060-AUS Reference Guide

Advertisement

loading