• Duress Code: If this option is selected and Code
14 is used to disarm the system, a duress report will
be sent as the system is otherwise disarmed
normally. User Code 14 will not arm the system, or
report duress, if the system is not armed.
• Guest Code: If this option is selected, Code 15 is
a guest code. It can be enabled by pressing [PIN]
[#] [8] [4]. It will remain active until the panel is
disarmed with any other valid code.
• Arming Warning: If this option is selected, the
alarm output will turn on for 2 seconds when the
panel is armed.
• Keypad Audible During Exit Delay: Selection of
this option will cause the keypad sounders to beep
during the exit delay time. A one second beep will
sound at 5 second intervals, changing to a 3-beep
tone at 10 and 5 seconds prior to the end of the
delay.
• Keyswitch Arming Warning: Selecting this option
will activate any output programmed as Intrusion,
Follow Burg Alarm, or Follow Burg Alarm and Fire
Alarm. The output will beep once (200 ms ON)
when a keyswitch toggle zone arms the system. A
double beep will occur (200 ms ON-OFF-ON) when
a keyswitch toggle zone disarms the system.
DS7060-AUS Reference Guide
 $GGUHVV   *HQHUDO &RQWURO
• Siren on Comm. Fail for Silent Zone: If
• Closing Ringback: If programmed, the keypad
• Swinger Shunt: If enabled, a zone can only alarm
• 50 Hz/60 Hz: Set to local power type. The panel
• Keypad Mode: Commercial Mode requires a PIN
• Quick Arm: If enabled, a PIN is not needed to arm.
Copyright © 1997-98 Detection Systems, Inc.
programmed, a silent zone will sound the alarm
outputs if the zone is in an alarm condition and the
system fails to communicate with the central
station.
sounders and Output 3 will activate for 2 seconds
after the system is armed and the closing report is
successfully sent. This requires Closing Ringback
and Closing Report to be programmed. If the panel
does not report to a central station, use "Arming
Warning" in Address 9.
or trouble up to three times per armed period. After
the third alarm or trouble, the zone will be bypassed
and a bypass report for this zone will be sent. Fire
zones are never swinger shunted.
clock is synchronized to the power line frequency.
60 Hz required for UL Listed Requirements.
number for all functions. Residential Mode only
requires a PIN number for disarming and silencing
alarms.
Note: Used only in conjunction with commercial
mode.
4/98