• Easy Exit: If the system is armed and there have
been no zones violated, then you can reenter a
Quick Arm Command without first disarming the
system. This allows you to change the arming level
or to restart the exit delay so you can exit through
an entry/exit zone.
• Force Arming Limit: If enabled, the system can
be armed when zones are violated or if an AC
power failure has occurred, by pressing the [Bypass
Key] after an arming command. If bypassing is not
allowed, a three beep error tone will sound and the
panel will return to standby mode.
Note: If "Auto Bypass" (Address 10) is enabled,
arming the panel will automatically bypass the
corresponding number of zones programmed into
Force Arming Limit. If "Auto Bypass" is disabled,
any zones that were programmed to be bypasses in
Address 02, may be Auto Bypassed.
• Auto Bypass: If enabled, the system will
automatically bypass faulted zones when an arming
command is used. If bypassing is not allowed on
the "Not Ready" zone, a three beep error tone will
sound, and the panel will return to standby mode.
Note: When enabling Auto Bypass, it may be
desirable to program "Force Arming Limit" (Address
10). If "Force Arming Limit" is set to 0, Auto Bypass
will allow bypassing of any zone that was
programmed to be bypassed by Address 02. If
"Force Arming limit" is programmed between 1 and
6, this is the maximum number of zones that can be
Auto Bypassed.
 $GGUHVV   .H\SDG $VVLJQPHQW
The keypad type (LED or Alpha) or no keypad must be
programmed.
Page 12
 $GGUHVV  WKUX   $OSKD /DEHO
• Address 12: Private Label - The private label will
• Address 13: Zone 1 Alpha Label:
• Address 14: Zone 2 Alpha Label:
• Address 15: Zone 3 Alpha Label:
• Address 16: Zone 4 Alpha Label:
• Address 17: Zone 5 Alpha Label:
• Address 18: Zone 6 Alpha Label:
Example: To program "ABC Alarm" as the Private Label
Enter the Programmer's Mode:
Enter the Program Address:
Enter:
Enter:
Enter:
Enter:
Enter:
Enter:
Enter:
Enter:
Enter:
Enter:
Copyright © 1997-98 Detection Systems, Inc.
display when the system is Ready to Arm and when
it is Armed.
[9] [8] [6] [#] [0]
[1] [2] followed by [#]
[2] for the letter "A" then press the right
arrow key for the next letter.
[2] twice for the letter "B" then press the right
arrow key for the next letter.
[2] three times for the letter "C" then press
the right arrow key for the next letter.
[1] until you have a blank space. Note:
moving the cursor to the left does not create
a space. Spaces must be programmed into
the Alpha using the [1] key.
[2] for the letter "A" then press the right
arrow key for the next letter.
[System Reset] This key is the upper/lower
case toggle.
[5] three times for the letter "l" then press the
right arrow key for the next letter.
[2] for the letter "A" then press the right
arrow key for the next letter
[7] twice for the letter "r" then press the right
arrow key for the next letter.
[6] for the letter "m".
[#] Program the next address, program a
different address, or exit the Programmer's
Mode.
DS7060-AUS Reference Guide

Advertisement

loading