 $GGUHVV   2SHQ&ORVH 'XUHVV
5HSRUW
• Open: This report is sent when the system has
been disarmed. In Contact ID, SIA or 4/9 formats,
the user number for the person who disarmed the
system will be sent with this report. To send the
user number along with an Open Report in other
formats, program the extended digit of the report
as F ([*] [5]). The Open Report will only be sent if a
Close Report was sent previously.
• Close: This report is sent when the system has
been armed. In Contact ID, SIA or 4/9 formats, the
user number for the person who armed the system
will be sent with this report. To send the user
number along with a Close Report in other formats,
program the extended digit of the report as F ([*]
[5]).
• Duress: This report is sent when the system is
disarmed using a duress code. The user number
will not be sent along with this report.
• Partial Close: This report is sent when the system
is armed partially, or force armed.
• First Open After Alarm: This report is sent when
the system is disarmed after an alarm has
occurred. It will also be sent if the system is
already disarmed and a user number is entered to
silence a 24-hour or fire zone.
DS7060-AUS Reference Guide
 $GGUHVV   %DWWHU\ $& 5HSRUW
• Low Battery Report: This report is sent when a
• Low Battery Restoral Report: This report is sent
• AC Failure Report: This report is sent after an AC
• AC Failure Restoral Report: This report is only
 $GGUHVV   3URJUDPPLQJ 5HSRUW
• Remote Programming Successful: This report is
• Remote Programming Unsuccessful: This
• Local Programming Successful: This report is
Copyright © 1997-98 Detection Systems, Inc.
low battery condition occurs.
when a low battery condition restores.
failure condition occurs. AC failure reports will only
be sent along with other reports if Address 50 is
set to "000." Otherwise reports will be sent after the
delay set in Address 50.
sent along with other reports if Address 50 is set to
"000." Otherwise reports will be sent after the delay
set in Address 50.
sent after a Remote Programming session, if the
session was terminated properly.
report is sent after a Remote Programming
session, if an error occurs or session doesn't
terminate properly.
sent when local programmer's mode is exited and
no error is associated with the programming.
4/98