Table of Contents

Advertisement

DS6100
The voltage available on the input connector, between pins A and B, is
physically the same as used to power the scanner.
The electrical features of these inputs are:
Maximum voltage
Maximum current

2.5.5 Outputs

Apart from the main and auxiliary interface outputs on the 19-pin circular
connector (Figure B,
for external devices.
Pin
A
B
C
D
E
F
G
H
A D.C. output voltage, the same as that powering the DS6100, is present
between pins A and B. This may be used to power external devices: electrical
isolation between the scanner and external devices is lost in this case.
The NO READ output activates when a code signalled by the presence
sensor is not decoded.
The RIGHT output is used to signal the presence of a right code, thus a good
decode condition.
The NO READ and RIGHT outputs are all level or pulse programmable: a 50
ms pulse is generated in the second case. Further programming information
is supplied in the WinHost Help File. These outputs are created using
optoisolated Darlington drivers and supply both the collector and emitter in
output, allowing both loads referenced to ground and to the power supply to
be driven.
2.26 - Installation
30 V
25 mA
), there are also indicator and power supply outputs
12
Name
GND
VS
NO READ-
NO READ+
RIGHT-
RIGHT+
SPS-
SPS+
Function
power for external devices -
power for external devices +
no read output
no read output
right code output
right code output
slave presence sensor
slave presence sensor