Datalogic DS6100 Installation Manual page 52

Table of Contents

Advertisement

DATALOGIC
Code
= Interleaved 2/5 and Code 39 according to Datalogic Barcode Test Chart
PCS
= 0.90
"Pitch" angle
= 0°
"Skew" angle
= 10°
"Tilt" angle
= 0°
Operating mode = linear
Figure 3.5 - Reading diagram conventions and operating conditions
0.30 mm
0.50 mm
1.00 mm
CONDITIONS
A
=
minimum reading distance
B
=
maximum reading distance at 50° aperture
C
=
maximum reading distance at 30° aperture
D
=
laser beam aperture
Figure 3.6 - Reading distances for DS6100
C
B
A
D
30° 50°
50°
30°
DS6100
30° aperture angle
50° aperture angle