Table Of Contents; Servicing Notes - Sony MXD-D3 Service Manual

Compact disc minidisc deck
Table of Contents

Advertisement

TABLE OF CONTENTS

1.
2.
................................................................... 17
3.
......................................................... 18
4.
.............................................................. 24
5.
6.
Schematic Diagrams ....................................................... 41
6-3. Schematic Diagram - BD (CD) Board - ....................... 43
- MAIN (1/3) /LOADING Boards - .............................. 47
- MAIN (Side B)/LOADING Boards - ......................... 51
- DISPLAY/PWSW/HP Boards - .................................. 52
- DISPLAY/PWSW/HP Boards - .................................. 53
6-14. Printed Wiring Board - TRANS Board - ...................... 54
6-15. Schematic Diagram - TRANS Board - ......................... 55
6-16. Printed Wiring Board - SW Board - ............................. 55
6-17. Schematic Diagram - SW Board - ................................ 55
6-18. IC Pin Function Description ........................................... 63
7.
8.
SAFETY-RELATED COMPONENT WARNING!!
LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS
AND IN THE PARTS LIST ARE CRITICAL TO SAFE
OPERATION. REPLACE THESE COMPONENTS WITH
SONY PARTS WHOSE PART NUMBERS APPEAR AS
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB-
LISHED BY SONY.
4
.................................... 2
............................................... 4
......................... 30
................................................ 72
............................... 79
SECTION 1

SERVICING NOTES

SAFETY CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs,
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex-
amples of a passive VOM that is suitable. Nearly all battery
operated digital multimeters that have a 2 V AC range are suit-
able. (See Fig. A)
To Exposed Metal
Parts on Set
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0
SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE
DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ
DE FONCTIONNEMENT. NE REMPLACER CES COM-
POSANTS QUE PAR DES PIÈCES SONY DONT LES
NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
AC
1.5 k Ω
voltmeter
(0.75 V)
Earth Ground

Hide quick links: