Electrical Wiring; Gas Line Connection - kozy heat 911 Installation Manual

Table of Contents

Advertisement

Electrical wiring must be installed by a licensed electrician.
ATTENTION
This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with
Nation Electric Code, ANSI/NFPA 70-latest edition, or the Canadian Electric Code, CSA C22.1
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
WARNING
directly into a properly grounded three-prong receptacle. Do not cut or remove grounding prong from this plug.
Do not allow excess cord to touch fireplace.
GAS CONVERSION
This fireplace is manufactured for use with Natural Gas. Follow instructions included with conversion kit if converting to LP gas.
The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in
ATTENTION
accordance with the requirements of the ANSI Z223.1 installation code.
Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.
If not, follow ANSI 223.1.
CAUTION
Commonwealth of Massachusetts: Installation must be done by a licensed plumber of gas fitter.
A listed (and Commonwealth of Massachusetts approved) 1/2" (13mm) T-handle manual shut-off valve and flexible gas
connector (included) are connected to the 1/2" (13mm) control valve inlet. If substituting for these components, please consult
local codes for compliance.
This fireplace is equipped with a 3/8"(10mm) x 18" (457mm) long flexible gas connector and manual shut-off valve. The gas
line should be run to the point of connection where the shut-off valve and flexible gas line will connect.
NOTE
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at pressures in excess of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any
pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.
The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating
IMPORTANT
conditions and was determined independently of any installed system.
If installing this insert into minimum opening dimensions, the gas line may need to be run after placement due to space
limitations.
NOTE
If installing this gas fireplace insert into a factory-built fireplace and the factory-built fireplace has no access hole provided, an
access hole of 1 ½"(38 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like
manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.
IMPORTANT
Do not run gas line in a manner that would obstruct fan operation.
MINIMUM INLET GAS PRESSURE
MAXIMUM INLET GAS PRESSURE

ELECTRICAL WIRING

GAS LINE CONNECTION

NATURAL GAS
5" WC (1.25 kPa) (7" WC (1.74 kPa) (recommended)
10.5" WC (2.62 kPa)
LP GAS
11" WC (2.74 kPa) (recommended)
13" WC (3.24 kPa)