RUN THE GAS LINE
Caution: Installation of a gas line must only be performed by a qualified person in accor-
GAS CONVERSIONS:
This fireplace is standard for use with Natural Gas. An LP Gas conversion kit is included with this fireplace.
Follow instructions included with this conversion kit.
LP Gas Conversion Kit: #OCK-S53 - used to convert a Natural Gas appliance to LP Gas
Natural Gas Conversion Kit: #OCK-S38 - used to convert an LP appliance to Natural Gas.
NOTE: This fireplace is equipped with a flexible gas connector and manual shut off valve.
NOTE: The gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect.
CAUTION: The manual shut-off valve or flexible gas tubing must not extend outside of the unit cavity. See the
WARNING label affixed to the flexible tubing for additional installation instructions and warnings.
NATURAL GAS:
The minimum inlet gas supply pressure: 7.0 inches W.C. (recommended)
Orifice size: 38
LP GAS:
The minimum inlet gas supply pressure: 11.0 inches W.C. (recommended)
Orifice size: 53
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous
operating conditions and was determined independently of any installed system.
NOTE: For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating
methods.
dance with local building codes.
The maximum inlet gas supply pressure: 10.5 inches W.C.
Manifold pressure: 3.5 inches W.C.
Manifold pressure (lo setting): 1.7 inches W.C.
Input: 26,000 BTU‟s
The maximum inlet gas supply pressure: 13.0 inches W.C.
Manifold Pressure: 10.0 inches W.C.
Manifold Pressure (lo setting): 6.5 inches W.C.
Input: 26,000 BTU'S
Page 16
Efficiency: 71.2%
AFUE: 67%
Efficiency: 73%
AFUE: 66.7%
(included standard)