6
Dimensional drawing & centre of gravity

6 - 1 Dimensional drawing

FHQ35B
Obstacle
Floor side
Note:
1. Location of unit's name plate: bottom of fan housing inside the suction
grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the machine)
attached.
2
(0.5 mm
x 2 Wicks x O.D. J5.4)
FHQ50B
Obstacle
Floor side
Note:
1. Location of unit's name plate: bottom of fan housing inside the suction
grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the machine)
attached.
2
(0.5 mm
x 2 Wicks x O.D. J5.4)
• Indoor Units • R-410A • FHQ-BVV1B
Hanging bolt
(Hanging position)
30 or more
(Service space)
View from the front
Drain pipe connection
VP20
(For left piping)
(Hanging position)
Hanging bolt
30 or more
(Service space)
View from the front
Drain pipe connection
VP20
(For left piping)
• Split Sky Air • Indoor Units
Position slit hole for taking out in piping back
(View from the front)
Position: hole of wall for taking out in piping back
(View from the front)
30 or more
(Service space)
Brand name plate
(Note 2)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection J9.5 flare
5 Liquid pipe connection J6.4 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole - slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26
Position slit hole for taking out in piping back
(View from the front)
Position: hole of wall for taking out in piping back
(View from the front)
30 or more
(Service space)
Brand name plate
1 Air discharge grille
(Note 2)
2 Air suction grille
3 Air filter
4 Gas pipe connection J12.7 flare
5 Liquid pipe connection J6.4 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole - slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26