Dimensional Drawing & Centre Of Gravity; Dimensional Drawing - Daikin FXCQ20MVE9 Technical Data Manual

2-way blow ceiling mounted cassette
Table of Contents

Advertisement

5
Dimensional drawing & centre of gravity

5 - 1 Dimensional drawing

FXCQ20-25-32MVE
820 (Suspension position)
990 (Ceiling opening)
(knock hole)
6-M5 hole (Circumference)
Fresh air intake
FXCQ40-50MVE
1035 (Suspension position)
1205 (Ceiling opening)
(knock hole)
hole (Circumference)
Fresh air intake
• Indoor Units • 2-Way Blow Ceiling Mounted Cassette • FXCQ-MVE9
Branch duct connection
BView
- Require space
Decoration panel
Brand name plate (Note 3)
or more
or more
A View
BView
- Require space
Decoration panel
Brand name plate (Note 3)
or more
or more
A View
®
• VRV
Systems • Indoor Units
Nr
Name
1
Liquid pipe connection port:
2
Gas pipe connection port:
3
Drain pipe connection port:
4
Power wiring port
5
Air discharge port
6
Air suction grille
7
Port for water supply
8
Drain hose
9
Socket for drain
NOTES
1
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
2
When installing an optional accessory, refer to the installation
drawings.
3
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
4
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.
Glass fiber of polyethylene foam.
or more
Nr
Name
1
Liquid pipe connection port:
2
Gas pipe connection port:
3
Drain pipe connection port:
4
Power wiring port
5
Air discharge port
6
Air suction grille
7
Port for water supply
8
Drain hose
Branch duct connection
9
Socket for drain
NOTES
1
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
2
When installing an optional accessory, refer to the installation
drawings.
3
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
4
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.
Glass fiber of polyethylene foam.
or more
Description
ø 9.5 flare connection
ø 15.9 flare connection
VP25 (O.D. ø 32, I.D. ø 25)
O.D. ø 32
3D039405A
Description
ø 9.5 flare connection
ø 15.9 flare connection
VP25 (O.D. ø 32, I.D. ø 25)
O.D. ø 32
3D039406
3
1
5
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents