Daikin FHQ35CBVEB Operation Manual
Hide thumbs Also See for FHQ35CBVEB:

Advertisement

Quick Links

SPLIT SYSTEM
SYSTEM
MODELS
(Ceiling Suspended type)
SPLIT SYSTEM
FHQ35CBVEB
FHQ50CBVEB
FHQ60CBVEB
FHQ71CBVEB
FHQ100CBVEB
FHQ125CBVEB
FHQ140CBVEB
VRV SYSTEM
FXHQ32AVEB
FXHQ63AVEB
FXHQ100AVEB
OPERATION MANUAL
Air Conditioners
Air Conditioners
English
Deutsch
Français
Español
Italiano
Ελληνικά
Nederlands
Português
Русский
Türkçe

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FHQ35CBVEB

  • Page 1 OPERATION MANUAL English SPLIT SYSTEM Air Conditioners SYSTEM Air Conditioners Deutsch MODELS Français (Ceiling Suspended type) SPLIT SYSTEM VRV SYSTEM Español FHQ35CBVEB FXHQ32AVEB FHQ50CBVEB FXHQ63AVEB FHQ60CBVEB FXHQ100AVEB Italiano FHQ71CBVEB FHQ100CBVEB FHQ125CBVEB Ελληνικά FHQ140CBVEB Nederlands Português Русский Türkçe...
  • Page 2 Thank you for purchasing this product unit. Σας ευχαριστούμε που αγοράσατε αυτό το προϊόν. Carefully read this operation manual to ensure proper Διαβάστε προσεκτικά αυτό το εγχειρίδιο λειτουργίας operation. για να διασφαλιστεί η σωστή λειτουργία. After reading the manual, file it away for future refer- Μετά...
  • Page 3  DISPOSAL REQUIREMENTS  VORSCHRIFTEN ZUR ENTSORGUNG  INSTRUCTIONS D’ÉLIMINATION  REQUISITOS PARA LA ELIMINACIÓN  SPECIFICHE DI SMALTIMENTO  ΠΡΟΫΠΟΘΕΣΕΙΣ ΑΠΟΡΡΙΨΗΣ  VEREISTEN VOOR HET OPRUIMEN  REQUISITOS PARA A ELIMINAÇÃO Disposal requirements Specifiche di smaltimento Your air conditioning product is marked with this symbol. This means that Il climatizzatore è...
  • Page 4: Table Of Contents

    CONTENTS only be done by persons described in manual. 1. SAFETY PRECAUTIONS....... 1 2. WHAT TO DO BEFORE OPERATION... 3 The appliance is not intended for use by unattended young 3. OPERATION RANGE........5 children or persons who are incompetent to operate air 4.
  • Page 5 Do not use the air conditioner in places with excessive CAUTION oily smoke, such as cooking rooms, or in places with flammable gas, corrosive gas, or metal dust. Children should be watched so that they do not play Using the air conditioner in such places may cause a fire or with the indoor unit or its remote controller.
  • Page 6: What To Do Before Operation

    To avoid injury, do not touch the air inlet or aluminum Measuring points for fins of the air conditioner. the residual voltage Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the unit or refrig- A1P X1M erant piping, air filter dirt or drain blockage may cause drip- ping, resulting in fouling or failure of the object concerned.
  • Page 7 PRECAUTIONS FOR GROUP CONTROL ature sensor to individually control the tempera- ture according to the set temperature on the SYSTEM OR TWO REMOTE CONTROLLERS remote controller. CONTROL SYSTEM • Two remote controllers control system This system provides two other control systems Two remote controllers control one indoor unit (In beside individual control (one remote controller con- case of group control system, one group of indoor...
  • Page 8: Operation Range

    3. OPERATION RANGE 4. INSTALLATION SITE If the temperature or the humidity is beyond the following condi- Regarding places for installation tions, safety devices may work and the air conditioner may not • Is the air conditioner installed at a well-ventilated operate, or sometimes, water may drop from the indoor unit.
  • Page 9: Operation Procedure

     CHARACTERISTICS OF THE HEATING 5. OPERATION PROCEDURE OPERATION (HEATING OPERATION AND • Operating procedure varies with heat pump type AUTOMATIC HEATING OPERATION) and cooling only type. Contact your local dealer to START OF OPERATION confirm your system type. • It generally takes a longer time for indoor temper- •...
  • Page 10 Regarding outside air temperature and heat- AIRFLOW DIRECTION ADJUST ing capacity • The heating capacity of the air conditioner • There are 2 ways of adjusting the airflow direction. declines as the outside air temperature falls. In (When the operation stops, the horizontal blades such a case, use the air conditioner in combina- at the air outlet (Up and down direction adjust- tion with other heating systems.
  • Page 11: Optimum Operation

    MOVEMENT OF THE HORIZONTAL BLADE B. LEFT AND RIGHT DIRECTION For the following conditions, micro computer con- • The left and right airflow direction can be fixed at trols the airflow direction so it may be different from the desired position manually. the display.
  • Page 12: Maintenance (For Service Personnel)

    • Turn off the power circuit breaker when it is not in CAUTION use for a long period. When the power circuit • Do not wash the air conditioner with water. breaker is turned on, small amount of power is It may cause electric shocks or a fire due to leak- consumed even if the air conditioner is not in oper- age.
  • Page 13 1. Open the suction grille. NOTE Slide the knob to the arrow direction and slowly • Do not wash the air filter with water of 50°C or open the grille. higher. It may cause decolorization and defor- mation. • Do not heat the filter with fire. It may cause burning.
  • Page 14 2 Keep holding the clips at the upper part of the 7. Close the suction grille. suction grille and pull them to frontward. Slide all the knobs in the reverse order men- tioned in the Clause 1 and securely fix them. HOW TO CLEAN AIR OUTLET, OUTSIDE PANEL, AND REMOTE CONTROLLER •...
  • Page 15: Not Malfunction Of The Air Conditioner

    HEATING OPERATION within 6 hours after the 9. NOT MALFUNCTION OF THE power is supplied to the air conditioner. AIR CONDITIONER • Some models perform the following operation to protect the devices. 9-1. FHQ If the HEATING OPERATION is performed within The following symptoms do not indicate air con- 6 hours after the power is supplied to the air con- ditioner malfunction...
  • Page 16 For comfortable use, do not turn off the IV. THE AIRFLOW DIRECTION IS DIFFERENT power circuit breaker during seasonal use of FROM THE SETTING, OR THE AIRFLOW the HEATING OPERATION. DIRECTION IS DIFFERENT FROM THE DIS- PLAY ON THE REMOTE CONTROLLER •...
  • Page 17: Trouble Shooting

    • When the air conditioner is changed over X. THE AIR CONDITIONER DOES NOT COOL to the HEATING OPERATION after the EFFECTIVELY DEFROST OPERATION and in the • The air conditioner is operating in the DEFROST OPERATION. PROGRAM DRY OPERATION. Moisture generated by defrost becomes This is because program dry mode operates steam and will float around.
  • Page 18 2. If the air conditioner stops after operating the • Check if direct sunlight enters the room (when air conditioner. cooling). Use curtains or blinds. • Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles. •...
  • Page 19 • If the display “ ”, “UNIT No.”, and the OPERA- TION lamp flash and the “MALFUNCTION CODE” appears. (In case of BRC1C, BRC1D) OPERATION lamp UNIT No. INDOOR UNIT No. in INSPECTION which a malfunction occurs display MALFUNCTION CODE Measure: Notify your local dealer and inform malfunction code of the display.
  • Page 20 3P303408-6Q EM15A026 (1602) HT...