Dimensional Drawing & Centre Of Gravity; Dimensional Drawing - Daikin VRVIII Series Technical Data Manual

Air conditioning systems bs box
Hide thumbs Also See for VRVIII Series:
Table of Contents

Advertisement

4
Dimensional drawing & centre of gravity

4 - 1 Dimensional drawing

BSVQ250PV1
3
BSVQ160PV1
4
• BS Units • BS UNITS • BSVQ100-250P8B
(Suspension bolt pitch)
400 or more
(Servicing space)
Inspection door
(Note 2.)
Location of unit's name plate - - - right side of electric box
(Suspension bolt pitch)
Inspection door
(Note 2.)
Location of unit's name plate - - - right side of electric box
®
• VRV
Systems • BS Units
300 or more
300 or more
(Servicing space)
(Servicing space)
Servicing space
1
2
3
400 or more
(Servicing space)
4
(In case of use Attached pipe)
5
6
7
8
9
(Note 1.)
10
1
2
3
4
250 or more
250 or more
(Servicing space)
(Servicing space)
Servicing space
1
2
3
4
5
(Note 1.)
6
7
8
9
10
1
2
3
4
Nr
Name
Suction gas pipe connection port
ø22.2mm brazing connection
HP/LP gas pipe connection port
ø19.1mm brazing connection
Liquid pipe connection port
ø9.5mm brazing connection
Gas pipe connection port
ø22.2mm brazing connection
Liquid pipe connection port
ø9.5mm brazing connection
Electric box (note 1.)
Suspension brackets
M8 ~M10
Grounding terminal
M4
Attached pipe (1) (Note. 3)
ø19.1mm brazing connection
Attached pipe (2) (Note. 3)
ø15.9mm brazing connection
N
OTES
Electric box can also be fixed on the other side of the unit.
Be sure to install a inspection door at electric box side.
Attached pipe (1) and attached pipe (2) is used in case of
connecting with indoor capacity index more than 160 and less
than 200 In case of connecting one indoor unit of 200 type, only
gas pipe connection port need Attached pipe (1).
Small sound will be made when changing over the motor
operated valve, which may be disturbing. Do not install it at the
place such as bedroom under roof.
350 or more
(Servicing space)
(In case of use Attached pipe)
Nr
Name
Suction gas pipe connection port
ø15.9mm brazing connection
HP/LP gas pipe connection port
ø12.7mm brazing connection
Liquid pipe connection port
ø9.5mm brazing connection
Gas pipe connection port
ø15.9mm brazing connection
Liquid pipe connection port
ø9.5mm brazing connection
Electric box (note 1.)
Suspension brackets
M8 ~M10
Grounding terminal
M4
Attached pipe (1) (Note. 3)
ø19.1mm brazing connection
Attached pipe (2) (Note. 3)
ø15.9mm brazing connection
N
OTES
Electric box can also be fixed on the other side of the unit.
Be sure to install an inspection door at electric box side.
Attached pipe is only used in case of connecting with indoor unit
capacity index 150 or more and 160 or less.
Small sound of refrigerant will be made, which may be
disturbing.
Do not install it at the place such as bedroom under roof.
Description
3D056012A
350 or more
(Servicing space)
Description
3D058004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bsvq250pv18Bsvq-p8b seriesBsvq100pv18Bsvq160pv18