Dimensional Drawing & Centre Of Gravity; Dimensional Drawing - Daikin VRVIII-S Series Technical Data Manual

Indoor units 4-way blow ceiling suspended cassette
Hide thumbs Also See for VRVIII-S Series:
Table of Contents

Advertisement

6
Dimensional drawing & centre of gravity

6 - 1 Dimensional drawing

FXUQ71MA
Drain connection
location for upper
piping
Drain pipe can
be raised up to 0mm from the top surface of the product.
50
Brand name plate (Note 2)
FXUQ100-125MA
Drain connection
Drain connection
location for upper
location for rear
piping
piping
Drain pipe can be
raised up to 500mm from the top surface of the product.
Brand name plate (Note 2)
• Indoor Units • 4-WAY BLOW CEILING SUSPENDED CASSETTE • FXUQ-MAV1
Drain connection
location for rear
piping
790 Suspension position
790 Suspension position
®
• VRV
Systems • Indoor Units
1500mm
or more
Required space
1500mm
or more
1500mm
or more
When closing the discharge grill, the required space is
30mm or more. (Note 3)
Nr
1
2
3
4
Suspension bolt
5
4-M3~M10
Height of suspension bracket
6
7
8
9
10 Accessory drain elbow
1000mm or more (Requierd space)
1
2
3
1500mm
or more
Required space
1500mm
or more
1500mm
or more
When closing the discharge grill, the required space is
30mm or more. (Note 3)
Nr
1
2
3
4
Suspension bolt
5
4-M3~M10
6
Height of suspension bracket
7
8
9
10 Accessory drain elbow
1000mm or more (Requierd space)
1
2
3
1500mm
or more
Part name
Description
Liquid pipe connection
ø9.5 Flare connection
Gas pipe connection
ø15.9 Flare connection
Drain pipe connection
VP20
Air outlet
Air suction grille
Corner decoration cover
Right pipe/wiring connection
Rear pipe/wiring connection
Pipe through cover
NOTES
Location for manufacture's label: on bell mouth.
This is where the signal of infrared remote control is received.
Refer to the drawing of infrared remote control in detail.
When closing the discharge grill (2 or 3 way discharge), direction of pipe
connection will be limited, please refer to Installation manual..
3D013860D
1500mm
or more
Part name
Description
Liquid pipe connection
ø9.5 Flare connection
Gas pipe connection
ø15.9 Flare connection
Drain pipe connection
VP20
Air outlet
Air suction grille
Corner decoration cover
Right pipe/wiring connection
Rear pipe/wiring connection
Pipe through cover
NOTES
Location for manufacture's label: on bell mouth.
This is where the signal of infrared remote control is received.
Refer to the drawing of infrared remote control in detail.
When closing the discharge grill (2 or 3 way discharge), direction of pipe
connection will be limited, please refer to Installation manual..
3D044898B
3
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents