Basic software procedures
Ê Choose the CPU status tab.
Ê Select the CPU which shows the pre-failure status.
Ê Click on Reset Status.
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific processor:
Ê Log in as root.
Ê Enter the command below, followed by [ENTER]:
– For rack and tower servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
– For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
I
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
Ê If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all processors:
Ê Log in as root.
Ê Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
88
Upgrade and Maintenance Manual
CX2550 M1