Tempest I
AK7000BS
AK7036BS
AK7042BS
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
SEP13.0101 © 2013 Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS

Advertisement

loading

Summary of Contents for Zephyr AK7000BS

  • Page 1 Tempest I AK7000BS AK7036BS AK7042BS Model number: Serial Number: Date of Purchase: Sales Dealer: SEP13.0101 © 2013 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifi cations ............... Mounting the Range Hood 9-10 ........Horizontal Conversion 11-12 ..........PBD-1200A Dual Blower 13-14 .......... FEATURES & CONTROLS Touch Controls &...
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. No for use over an outdoor grill.
  • Page 6: Installation

    MODELS: AK7000BS, AK7036BS, AK7042BS PARTS SUPPLIED 1 - Hood 2 - Baffl e fi lters (3 - AK7036BS and AK7042BS) 2 - Halogen light bulbs (pre-installed) 1 - Single internal blower and blower plate (pre-installed) 1 - Rectangular starting collar (for single blower horizontal ducting) 1 - 8”...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
  • Page 8 www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fi...
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options Ductless Recirculating...
  • Page 10 www.zephyronline.com *9 1/2” **14 3/16” 3 1/2” 1 5/8” 12” 6” *8 1/8” 2” 8 9/16” 34˚ **14 5/16” **10 3/8” 11” 3” 1” *7 7/8” 22 1/2” **9 15/16” R 9/16” side 29 7/8” (30”) 35 7/8” (36”) 41 7/8” (42”) * Single Blower Dimension ** Dual Blower Dimension 3 1/4”...
  • Page 11 ELECTRICAL WARNING All Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 www.zephyronline.com For dual blower installation instructions please refer to page 13. If recirculating range hood refer to the manual included with ZRC-07xxxB recirculating kit or on our 5. Duct opening website prior to installing hood. Recirculating kit cutout compatible with 650cfm single internal blower only. For Mounting Under a Kitchen Cabinet duct/silver 1.
  • Page 13 This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below. NOTE: Horizontal ducting is only available for the single internal blower. NOTE: If horizontally ducting via 3 1/4”...
  • Page 14 www.zephyronline.com 5. Place blower inside hood as shown. 6. Attach blower to hood body from the back of hood using (4) previously removed blower screws and reconnect blower plug. 8. Attach top cover plate to top of hood body using 7.
  • Page 15: Pbd-1200A Dual Blower

    This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. PBD-1200A dual blower kit compatible only with AK7036BS and AK7042BS models. 1.
  • Page 16 www.zephyronline.com 7. Dual Blower screw mount locations. 8. Connect blower wire extrension cable from PBD-1200A kit to new blower. Connect both blower plugs. 9. Place 10” round adapter (included with PBD- 1200A) on top of hood and secure with (4) M3.5 x 8 screws.
  • Page 17: Lights

    Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
  • Page 18 www.zephyronline.com Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to be replaced after every 120 hours of use.
  • Page 19 Baffle Filter Clean Reminder Aa set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
  • Page 20: Maintenance

    The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
  • Page 21 2. Pivot front of fi lter downward. 3. Remove fi lter by pulling away from hood. Replacing Baffle Filters Hood Model: Part No. Qty. to Order. AK7000BS 50210020 AK7036BS 50210020 AK7042BS 50210020 Recirculating Kit (includes charcoal fi lters and air diverter) Hood Model: Part No.
  • Page 22 If bulbs are diffi cult to turn due to prolonged use, fi rmly attach the provided glass suction cup or use a rubber/ latex glove and turn counter clockwise. Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. For Zephyr part numbers please turn to page 25 of the manual.
  • Page 23: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR TEMPEST I Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 24 MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7000BS, AK7036BS Single Motor AK7042BS Dual Motor CIRCUIT DIAGRAM ACT 390 CFM - Fan Max. 355W @ 2.8A ACT 290 CFM - Fan Max. 255W @ 2.2A...
  • Page 25 Single Blower Fan Curve Diagram Dual Blower Fan Curve Diagram...
  • Page 26: Wiring Diagrams

    Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of two most commonly specifi...
  • Page 27 Dual Internal Blower Kit (w/ 1 blower) * PBD-1200A Recirculating Kit (30”) ** ZRC-7000B Recirculating Kit (36”) ** ZRC-7036B Recirculating Kit (42”) ** ZRC-7042B Backsplash w/Shelves (AK7000BS) AK0710 Backsplash w/Shelves (AK7036BS) AK0716 Backsplash w/Shelves (AK7042BS) AK0712 Universal Make-Up Air Damper, 650 CFM MUA008A Universal Make-Up Air Damper, 1200 CFM MUA010A To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 28 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows:...
  • Page 29 Tempest I AK7000BS AK7036BS AK7042BS Numéro de modèle : Numéro de série : Date d’achat : Détaillant: SEP13.0101 © 2013 Zephyr Corporation LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 30 www.zephyronline.com...
  • Page 31 MISE EN GARDE DE SÉCURITÉ .....2-3 ..............LISTE DU MATÉRIEL ....................... INSTALLATION Feuille de calcul pour le conduit ................... Espace libre et hauteur de montage................Options d’installation pour le conduit ................Spécifi cations ........................Installation de la hotte 9-10 ......................
  • Page 32 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 33 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 34 MODÈLES : AK7000BS, AK7036BS, AK7042BS PIÈCES FOURNIES 1 - Hotte 2 - Filtres défl ecteurs (3 - AK7036BS et AK7042BS) 2 - Ampoules halogènes (préinstallées) 1 - Ventilateur interne simple et plaque du ventilateur (préinstallés) 1 - Collier de départ rectangulaire (pour conduit horizontal avec ventilateur simple) 1 - Collier de départ circulaire de 8”...
  • Page 35 Longueur x Longueur x Pièces de conduit Pièces de conduit Total Total Nombre utilisé Nombre utilisé 3-1/ 4” x 10” 1 pi 6” 30 pi rect., droit embout mural circ./registre 6” circ., droit 1 pi 6” 30 pi chapeau de toiture circ.
  • Page 36 www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage de la surface de la cuisinière au bas de la hotte ne devrait pas être inférieure à 26”. La hauteur de montage maximale ne devrait pas outrepasser 36”.
  • Page 37 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à...
  • Page 38 www.zephyronline.com *9 1/2” **14 3/16” 3 1/2” 1 5/8” 12” 6” *8 1/8” 2” 8 9/16” 34˚ **14 5/16” **10 3/8” 11” 3” 1” *7 7/8” 22 1/2” **9 15/16” R 9/16” Côté 29 7/8” (30”) 35 7/8” (36”) 41 7/8” (42”) * Dimensions pour le ventilateur simple ** Dimensions pour le ventilateur double Dessus...
  • Page 39 ÉLECTRICITÉ AVERTISSEMENT Tous les travaux électriques doivent être réalisés par un électricien qualifi é ou une personne avec l’expérience technique et le savoir-faire nécessaires. Pour votre sécurité, enlevez le fusible ou éteignez le disjoncteur de circuit avant de commencer l’installation. N’utilisez pas de rallonge électrique ou d’adaptateur avec cet électroménager.
  • Page 40 www.zephyronline.com Veuillez vous rapporter à la page 13 pour obtenir les instruction d’installation d’un ventilateur double. Si vous utilisez le mode de recirculation d’air, consultez le manuel 5. Ouverture accompagnant la trousse de récupération d’air ZRC-07xxxB pour le conduit ou notre site Web avant de procéder à l’installation de la hotte. La trousse de recirculation d’air n’est compatible qu’avec les ventilateurs internes simples de 650 pi3/min.
  • Page 41 Cette hotte standard est munie d’une entrée pour conduit vertical circulaire de 8”. Pour la convertir à un conduit horizontal circulaire de 8” ou rectangulaire 3-1/4” x 10”, veuillez suivre les instructions ci-dessous. NOTE : L’option du conduit horizontal n’est disponible que lors de l’utilisation d’un ventilateur interne simple.
  • Page 42 www.zephyronline.com 5. Placez le ventilateur à l’intérieur de la hotte, 6. Fixez le ventilateur au bâti de la hotte à partir comme illustré. de l’arrière de la hotte à l’aide des quatre (4) vis de ventilateur préalablement enlevées et rebranchez la fi che du ventilateur. 8.
  • Page 43 Cette hotte standard est munie d’une entrée pour conduit vertical avec un ventilateur simple. Pour la convertir d’un conduit vertical à ventilateur simple à un conduit vertical à ventilateur double, veuillez suivre les instructions ci-dessous. La trousse du ventilateur double PBD-1200A est compatible avec les modèles AK7036BS et AK7042BS. 1.
  • Page 44 www.zephyronline.com 7. Emplacements des vis du ventilateur 8. Branchez le câble d’extension de la trousse double. PBD-1200A kit au nouveau ventilateur. Branchez les deux fi ches des ventilateurs. 9. Placez l’adaptateur circulaire de 10” (compris dans la trousse PBD-1200A) sur la partie supérieure de la hotte et fi...
  • Page 45 Ventilateur Marche/Arrêt Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumières Allumer/Veilleuse/Éteindre Choix de 6 vitesses Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1. Vérification de la TCDA - La technologie de contrôle du débit d’air permet à...
  • Page 46 www.zephyronline.com Indicateur de changement des filtres à charbon (si installés) Lorsque la hotte est installée en mode de récupération d’air, elle est munie d’un jeu de filtres à charbon conçus pour purifier la fumée de cuisson et remettre l’air en circulation dans la maison. Ces filtres à charbon doivent être remplacés toutes les 120 heures d’utilisation.
  • Page 47 Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres. La fonction de rappel de nettoyage des filtres du microprocesseur indique automatiquement, à...
  • Page 48 La commande à distance radioélectrique est munie d’un aimant pour un entreposage facile. La commande peut être mise sur n’importe quelle surface magnétique, comme un réfrigérateur ou le support à commande Zephyr (FIG. 1). Le support à commande peut s’installer à une prise électrique standard pour un rechargement facile.
  • Page 49 2. Faites pivoter l’avant du fi ltre vers le bas. 3. Enlevez le fi ltre en le tirant vers vous. Remplacement des fi ltres défl ecteurs : Modèle de hotte : No de pièce Qtée à commander AK7000BS 50210020 AK7036BS 50210020 AK7042BS 50210020 Trousse de recirculation (comprend des fi...
  • Page 50 Les ampoules de remplacement sont disponibles dans les magasins spécialisés en éclairage. Procurez-vous des ampoules halogènes MR-16 (GU-10) de 35 W. Consultez la page 25 du présent guide pour obtenir les numéros de pièces Zephyr.
  • Page 51 TROUBLESHOOTING PROCEDURES FOR TEMPEST I Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 52 www.zephyronline.com TCDA 390 pi /min — Max. du ventilateur : 355W à 2,8 A TCDA 290 pi /min — Max. du ventilateur : 255W à 2,2 A...
  • Page 53 Diagrammes des courbes caractéristiques des ventilateurs simples Diagrammes des courbes caractéristiques des ventilateurs doubles...
  • Page 54 /min qu’une hotte peut extraire. La TCDA permet de contrôler la quantité maximale de pi /min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La TCDA permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à l’un des niveaux de pi /min les plus fréquemment utilisés...
  • Page 55 Trousse de recirculation d’air (30”) ** ZRC-7000B Trousse de recirculation d’air (36”) ** ZRC-7036B Trousse de recirculation d’air (42”) ** ZRC-7042B Dosseret et étagères (AK7000BS) AK0710 Dosseret et étagères (AK7036BS) AK0716 Dosseret et étagères (AK7042BS) AK0712 Registre universel d’air d’appoint, 650 pi...
  • Page 56 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...