Battery Specifiation; Telephone Connections; Detector Circuits; Normally Closed - IntelliSense SECURIT 900C Installation Manual

Hide thumbs Also See for SECURIT 900C:
Table of Contents

Advertisement

BATTERY SPECIFICATION
Maximum battery size is12 V 7.0 Ah. The panel requires a standby
battery to be fitted to provide power in the event of mains failure. A valve
regulated lead acid battery must be used. Observe the battery polarity.
Take great care to connect correctly.

TELEPHONE CONNECTIONS

The telephone connections, A & B on TB5, must be hard-wired to the
incoming telephone line. If the master socket is the NTE5/CTE5, the
connection can be carried out by the installation engineer otherwise the
network operator must make the connection. It must NOT be installed as
an extension to a payphone.
The panel is approved to EEC 98/482/EEC (R&TTE Directive, CTR21-see
Page 23 for a list of countries) for single terminal connection to the Public
Switched Telephone Network (PSTN) for
• Auto dialling
• Modem Communications
• Multiple Repeat attempts
• Operation with Call Process Monitoring (CPM) tone recognition

DETECTOR CIRCUITS

Normally Closed

Connections for up to eight alarm circuits.
devices must be used. The Zones may be programmed for normally
closed loop, double balanced or single End-of-Line resistor modes.
Programmed as Normally Closed (Factory default)
Wire a shorting link across any unused zones.
devices may be connected to each alarm circuit. These should be
connected in a series configuration. All zone tampers should be
wired in series and connected to the Zone Tamp terminals.
Programmed as Double Balanced End-of-Line
Wire a 1kΩ resistor across any unused zones. Only one device
should be connected to each alarm circuit. Wire the zone and
tamper connections in series with a 1kΩ resistor, fit a second 1kΩ
resistor across the alarm contact.
tampers should wired in series and be connected to the Zone
Tamp terminals.
• Auto Answer
• Auto Clearing
• Series Connections
Double Balanced EOL
7
Single End-of-Line
Normally closed detection
One or more
All other normally closed
BATTERY
SPECIFICATION
TELEPHONE
CONNECTIONS
DETECTOR
CIRCUITS
NORMALLY
CLOSED
DOUBLE
BALANCED

Hide quick links: