MOUNTING A REMOTE KEYPADS
1. Choose the keypad location and then mark the holes for mounting.
2. Make sure the cable is run through the backbox.
3. Screw the backbox in the selected position making sure it is not
twisted.
WIRING REMOTE KEYPADS
Use 4-core cable for connection of all remote keypads.
cable, making sure each wire goes to a like named terminal in the panel.
KPD goes to KPAD, + to AUX + and - to AUX -. Tamper is signalled
through the data bus so no separate connection is required.
Individual keypads do not need to be identified to the system. If more
than one remote keypad is used it can be either wired back the control
panel or daisy chained from another keypad.
parallel.

INITIAL POWER UP

Prior to the full wiring of the panel we recommend the following installation
stages.
The lid should remain off the main control panel.
connect the battery yet.
1. Connect the keypad, wire and switch on the mains supply.
keypad buzzer will start. This denotes a tamper alarm.
2. Enter 1 2 3 4. This will silence the keypad buzzer. This has now
acknowledged and cancelled the alarm. However, because the panel
lid is removed, the main tamper loop is open and the keypad will
indicate the tamper. This is normal.
3. Close the panel lid, enter 1 2 3 4, check the tamper LED clears.
4. Power down and complete the wiring of the control panel. NEVER
wire the control panel live.
5. Power back up, enter 1 2 3 4 to cancel the alarm and enter engineer
mode by entering
programming.

ENGINEER MODE

To enter engineer mode, enter the engineer code and then press the #
and * keys. The mains light will flash and the keypad will bleep twice to
signify the panel has entered engineer mode. Entering engineer mode
will abort any communications that may be in progress.
To exit engineer mode, close ALL tamper circuits and enter the # and *
keys.

ENGINEER RESET

To perform an engineer reset, enter the engineer code. There is no need
to enter engineer programme mode.
9 0 9 0 # *. The panel is now ready for
9
Connect the
All connections are in
Do NOT
The
MOUNTING
REMOTE
KEYPADS
WIRING
REMOTE
KEYPADS
INITIAL POWER
UP
ENTER & EXIT
ENGINEER
MODE
ENGINEER
RESET

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for IntelliSense SECURIT 900C

Table of Contents