Quick Programming Guide
The default codes
To enter Engineer mode CODE ,# *
To Exit Engineer mode
To review the program Menu 6
To review all other menus
The keypad display will step through the programmed settings.
Zone Programming Defaults
Menu 1
Zone
Full Set
1
Final Exit
2
Walkthrough
3
Alarm
4
Alarm
5
Alarm
6
Alarm
7
Alarm
8
Alarm
System options
Menu 4
41
Exit Time 0=Final Contact, 1-9 = time x 10sec
42
Entry Time
43
Bell Cut-off Time
44
Part Set Exit Earning
45
External Bell & Strobe in Part Set
46
External Bell & Strobe in Night Set
47
Trigger Output
48
Quick Set
49
Set Inhibit
Menu 5
51
Mains Fail Warning
52
Supplementary Entry Alarm Delay
53
Alarm Reset
54
Softkey Enable
55
Keypad Lockout
56
Bell Output Polarity
57
Alarm Output Polarity
58
Day Tamper Reset
59
Zone Mode
Master
Engineer
# *
- Enter 6 n 0, Where n is the second menu number
- Enter Menu No., 00
Menu 2
Part Set
Final Exit
Walkthrough
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
1-9 = time x 10sec
0=silent, 1=keypad only, 2=keypad & sounder
0=Neg applied, 1= Neg removed
0=Neg applied, 1= Neg removed
0=NC loops, 1=Double balanced, 2=EOL
1234
9090
The power LED will flash
The power LED will be constant
Menu 3
Key
Night Set
Final Exit
Final Exit
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Default
See Table 1
0=NO, 1=YES
0=NO, 1=YES
See Table 3
0=NO, 1=YES
See Table 4
Default
0=NO, 1=YES
0=NO, 1=YES
See Table 2
0=NO, 1=YES
0=NO, 1=YES
See Table 2
25
Zone types
0
Not used
1
Final Exit
2
Keyswitch
3
Alarm
4
Walkthrough
5
Tamper
6
Silent PA
7
Audible PA
8
Exit terminator
9
Fire
Table 1
3
Key
Time
3
1
1 Minute
8
2
2 Minutes
0
3
3 Minutes
1
4
4 Minutes
1
5
5 Minutes
3
6
10 Minutes
0
7
15 Minutes
0
8
20 Minutes
9
30 Minutes
0
0
0
Table 2
0
Alarm Reset
0
0
Customer
0
1
Engineer
0
2
Technistore
0
3
Engineer &
Technistore
0