SET INHIBIT MENU 49
Enter 49-(o). Enter 4 - 9 followed by the key corresponding to the Option
Number required from the table below:
Enter 0
Mains Fail (Default)
Enter 1
Low battery
Enter 2
Mains fail and Low battery
MAINS FAIL WARNING MENU 51
Enter 51-(o). Enter 5 - 1 followed by the key corresponding to the Option
Number required from the table below:
Enter 0
Off (Default)
Enter 1
Audible
SUPPLIMENTARY ENTRY ALARM DELAY MENU 52
Enter 52-(o). Enter 5 - 2 followed by the key corresponding to the Option
Number required from the table below:
Enter 0
Off (Default)
Enter 1
30 second full alarm & comms delay on (internal
sounders only).
ALARM RESET MODE MENU 53
Enter 53-(o). Enter 5 - 3 followed by the key corresponding to the Option
Number required from the table below:
Enter 0
Customer (Default)
Enter 1
Engineer
Enter 2
Technistore
Enter 3
Technistore & Engineer
KEYPAD SOFT KEY ALARMS MENU 54
Enter 54-(o). Enter 5 - 4 followed by the key corresponding to the Option
Number required from the table below:
Enter 0
Off (Default)
Enter 1
On
Keys must be held down together for two seconds for activation.
Panic
Press
constant tone emits.
Assistance
Press 4 and 6 together. Keypad displays scrolling LEDs with
fast pulse tone.
Fire
Press 7 and 9 together. Keypad displays scrolling LEDs
with slow pulse tone.
KEYPAD LOCKOUT MENU 55
Enter 55-(o). Enter 5 - 5 followed by the key corresponding to the
Option Number required from the table below. Keypad lockout occurs
after 20 incorrect keypresses and lasts for 10 minutes. No codes are
accepted during the lockout time.
Enter 0
Off (Default)
Enter 1
On
and # together. All LEDs (PA) illuminate and a
13
SET INHIBIT
MAINS FAIL
WARNING
SUPPLIMENTARY
ENTRY ALARM
DELAY
ALARM RESET
MODE
KEYPAD SOFT
KEY ALARMS
KEYPAD
LOCKOUT