FIREpOwER Fp-125, 135, 165
Follow these instructions only after referring to the Safety Instructions and Warnings chapter of this manual, and the instructions
in the Installation chapter
Check List Before Starting
POLARITY – DCEP (Direct Current Electrode Positive) or DCEN (Direct Current Electrode Negative)
WIRE FEED SPEED – 1 to 10
VOLTAGE RANGE SWITCH SETTING – 1 to 4 for FP-135, 165 an two switches and1-2 and Low-High for FP-125.
GAS FLOW RATE – 15 to 25 CFH (If shielding gas is required)
ELECTRODE WIRE STICK-OUT – approx 3/8" (10mm)

4.07 Welding Gun Positions

The welding gun should be held at an angle to the weld joint (see Secondary Adjustment Variables in Section 4.08). Hold
the gun so that the welding seam is viewed at all times. Always wear the welding helmet with proper filter lenses.
Do not pull the welding gun back when the arc is established. This will create excessive wire extension (stickout) and make a very
poor weld.
The electrode wire is not energized until the gun trigger switch is depressed. The wire may therefore be placed on the
seam or joint prior to lowering the helmet.
5º to 15º
Longitudinal
Angle
90º
Transverse
Angle
Figure 4-5: Butt and Horizontal Welds
10º Longitudinal Angle
30 to 60º
Transverse
Angle
Direction of Travel
Figure 4-6: Vertical Weld
Manual 0-5123
!
Direction of
Travel
Art: A-05105
10 to 20º Longitudinal
Angle
30º to 60º
Transverse
Angle
Art: A-05106
WARNING
CAUTION
5 to 15º
Longitudinal Angle
Direction of
Travel
Figure 4-7: Horizontal Fillet Weld
30 to 60º
Transverse Angle
Figure 4-8: Overhead
4-6
OpERATION
30 to 60º
Transverse Angle
Art: A-05107
Direction of Travel
5 to 15º
Longitudinal
Angle
Art: A-05108
Operation