Zip HydroTap ® Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms. Affix Model Number Label Here 801530 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 1 of 32...
Page 2
Notes Page 2 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Turn on the water and check for leaks. Flush the filter(s). Where applicable, programme the unit to suit the customer’s requirements. Page 4 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
General Product Features Thank you for purchasing a Zip HydroTap. Please read and follow these instructions carefully to ensure safe operation and trouble free service. If service is required, please call 1800 460 222 What is the Zip HydroTap ? The HydroTap units are under bench drinking water appliances with a dispensing tap mounted on a sink or bench, which may be used for residential or commercial applications.
Lifting Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging.
Zip HydroTaps are not to be exposed to the elements of nature Due to the process of continuous improvement, Zip Heaters reserves the right to change details mentioned in this manual, without notice. 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 7 of 32...
1 x User guide and Disabled lever Kit 1 x Quick start guide 1 off Installation instructions 3-in-1 and 4-in-1 (This book) Upgrade Kits Page 8 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
280 x 313 x 335 * Water from the H/T Mixer tap is unfiltered ** Add an extra 3-4 kg when full of water 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 9 of 32...
• The appliance must be placed with it’s base in a horizontal position. IMPORTANT! Do not proceed with the Installation if these requirements are not met. Page 10 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Zip Font, available as an accessory. 35mm hole HydroTap Sink 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 11 of 32...
750mm - Plug and Cord length is 1800mm Position the undersink unit according to the hose and cord lengths supplied Incoming water 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 13 of 32...
fi tted in the cold water supply line, Blue band Mixer Out Mixer IN from the isolation valve tee piece, to the mix- er tap. (See diagrams) Page 14 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Position the undersink unit according to the hose and cord lengths supplied Tee piece and Restrictafl ow valve COLD isolation valve (Not supplied) 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 15 of 32...
For high use applications, where the cupboard space temperature is near 35°C, or higher, a vent kit must be fitted. (Contact your local service centre for availability). Page 16 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Electric Supply 50Hz AC Elect fl ex and plug (black) - 1 meter length (with 90º Australian plug) Fixed Flow Rate L/min 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 17 of 32...
NOTE: Remove the backing plate for wall mounting Tilt Forward Lift UP Take care not to break the lower Release clips when removing or installing the Booster Installation Page 18 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Page 19
‘Bypass Out’ fitting to the water inlet of the booster unit (Marked Blue) and from the outlet of the booster unit (Marked Red) to the ‘Bypass IN’ fitting on the Zip HydroTap unit. Avoid exerting any mechanical pressure on the appliance. This can be achieved by applying a spanner on the flats of the inlet and outlet connections when tightening the braided hose connectors.
Set the appropriate selection on the Internal Filter Bypass Clearance valve located at the rear of the unit in accordance with Sections 5.1 and 5.2. Page 20 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter and only be filtered by the external filtration. This diverter valve is located at the rear panel of the Zip HydroTap undersink unit on the filter door side, see the image below.
Max. 280mm Note: The connection hose supplied with the cold inlet CANNOT be lengthened. : Not required for BO HydroTap. Page 22 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Note: The connection tubes supplied with the tap head and Booster assemblies CANNOT be lengthened. : Not required for BO HydroTap. 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 23 of 32...
Note: The connection hose supplied with the tap head assembly CANNOT be lengthened. : Not required for BA HydroTap. Page 24 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Note: The connection hoses supplied with the tap head and Booster assemblies CANNOT be lengthened. : Not required for BA HydroTap. 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 25 of 32...
Note: The connection hoses supplied with the HydroTap and mixer, CANNOT be lengthened. Page 26 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Note: The connection hoses supplied with the HydroTap and Booster CANNOT be lengthened. 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 27 of 32...
To start press 97.5 Calibrate commence the Boiling calibration procedure. This Calibrate Steam Vent button will take aprox 5-6 minutes. 53.0 Page 28 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
NOTE: For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user guide, located inside the fi lter housing access door. 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 29 of 32...
Overload Reset Internal fault Call Zip Service Call an electrician, a plumber, or Zip for a free call in Australia on 1800-638-633 for assistance, service, spare parts or enquiries. End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details.
Page 31
Notes 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014- V1.08 Page 31 of 32...
AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, US5099825 and SA2006/08043. Other patents are in force and patent applications are pending. Page 32 of 32 801530 - Zip HydroTap B, BA, BHA, BAHA, Installation Instructions - July 2014 - V1.08...
Need help?
Do you have a question about the HydroTap B160 and is the answer not in the manual?
Questions and answers