Installation, Maintenance and User Instructions
ZIP
Varipoint II
Direct unvented water heaters
Models:
VP103, VP153, VP103UB,
VP153UB
Please read these instructions carefully before commencing installation of this unvented
water heater. Please leave these instructions with the end user after installation.

Advertisement

Table of Contents
loading

Summary of Contents for Zip Varipoint II VP103

  • Page 1 Installation, Maintenance and User Instructions Varipoint II Direct unvented water heaters Models: VP103, VP153, VP103UB, VP153UB The terms ‘Zip’ and ‘Varipoint’ are registered trademarks Zip Heaters (UK) Ltd 14 Bertie Ward Way Dereham Norfolk NR19 1TE Telephone: 0845 6 005 005...
  • Page 2 inside back cover inside front cover...
  • Page 3: Table Of Contents

    Installation must only be undertaken by a competent person, familiar with unvented electric water heaters. The Zip Varipoint II must be installed in accordance with these instructions and all current legislation, codes of practice and regulations governing the installation of unvented hot water cylinders in force at the time of installation .
  • Page 4: Description

    VP153 Description These instructions should guide you through the installation, maintenance and use of the Zip Varipoint II, however, if you require any further information please call Zip customer service on 0845 6 005 005. • The Zip Varipoint II is an unvented water heater designed for connection directly to incoming mains water supply and can serve one or more outlets using conventional taps.
  • Page 5: Warnings

    • The appliance, its wiring and piping must not be modified in any way. • In case of malfunction isolate the power supply immediately. In case of leaks also isolate the water supply. Repairs must only be carried out by Zip Heaters (UK) Ltd or an authorised Zip service engineer.
  • Page 6: Cautions

    The Varipoint II is intended for connection to mains supply only. In any other case please contact Zip on 0845 6 005 005 for advice. • Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions. •...
  • Page 7: Technical Data

    Technical data Model VP103 VP153 VP103/UB VP153/UB Nominal supply voltage 1/N/PE 230V~ Power rating (kW) Rated Current (A) Element type Embedded Rod Water vessel Heavy Gauge Copper tested to 1.6 MPa (16 bar).. Maximum working pressure 0.6 MPa (6 bar). Temp.
  • Page 8: Spare Parts

    Spare parts Item Description Part No Element 2.2 kW for overbasin models VP0301 Element 2.2 kW for underbasin models VP0302 Thermostat VP0303 Ressettable cut-out VP0304 Element Gasket VP0317 Wall fixing bracket VP0322 Instructions. V1.01 Page 6 October / 2013...
  • Page 9: Installation

    The electrical installation including earthing and cross bonding should comply with the current IEE regulations and any local authority requirements. The Zip Varipoint II is designed for connection direct to the incoming mains water supply and accommodation must be made for the expanded water that will occur with each heating cycle.
  • Page 10: Positioning

    Positioning The Zip Varipoint II must be installed vertically. The connections should be at the rear of the unit. When facing the heater the hot supply (red) is to the left and the cold supply (blue) is to the right.
  • Page 11: Plumbing And Safety Control Arrangement

    The unit will be supported by being hung on a bracket fixed to a support wall, as shown (fig.1). Therefore it is important to ensure that the wall is strong and solid enough to fully support the unit when the tank is full. It is important to ensure when drilling the wall, that the selected position avoids any pipe work or electrical cabling.
  • Page 12: Installation Diagrams

    Installation diagrams (Underbasin model shown) fig.2 Length ‘A’ EXPANSION NEAREST RELIEF VALVE COLD WATER DRAW OFF SERVICE VALVE COLD COLD WATER SUPPLY DIAGRAM 1. Inlet pressure less than 0.35 MPa (3.5 bar) TO DRAIN VIA TUNDISH and expanded hot water can be accommodated in the pipework.
  • Page 13: Electrical Installation & Wiring

    230v AC SUPPLY ONLY, THIS APPLIANCE MUST BE EARTHED. The Zip Varipoint is pre-wired with a length of 3 core cable suitable for connection to a mains 230v supply. Connection must be made in accordance with the current IEE wiring regulations to a double pole isolating switch on a dedicated circuit or a double pole switched spur.
  • Page 14: Commissioning & Operation

    Commissioning & Operation. Check that all ‘Installation Requirements’ have been met. Check that all water and electrical connections are correct and tight. Open a hot water tap. Open the water mains isolating valve and allow the heater to fill. Close the hot water tap when water starts to flow from it.(The heater vessel should now be full).
  • Page 15: Maintenance

    12. Please pass these instructions on the person responsible for the building and it’s management. Maintenance Precautions. The Zip Varipoint II is an unvented electric water heater and only a competent person (electrician or plumber), familiar with unvented systems, should carry out any servicing and maintenance work on this unit 2. WARNING When the neon indicator light is extinguished the unit is still connected to the electricity supply, only by operating the ‘double pole isolating switch’...
  • Page 16: Schedule

    Schedule It is recommended that all key components of the heater system should be inspected on a regular basis, no greater than 12 monthly intervals, for the continued safe and efficient operation of the unit. The inspection should be carried out by a competent person (electrician or plumber) familiar with unvented systems and the components to be inspected should include the following: Expansion relief valve.
  • Page 17: Fault Finding

    Fault Finding Fault Possible cause Solution Reset and if the cut-out oper- ates again, isolate the unit and The thermostat has failed. contact the installer. Over temperature cut-out NB. Isolate the electrical operates. supply before removing the cover and ensure that the The thermostat is set at too cover is correctly replaced and high a temperature.
  • Page 18: Warranty

    Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.