12-MENU ENTRIES AND OPERATION
n - Chimney sweeper function (for maintenance operators only)
This function can only be activated when the boiler is on and power is supplied, and it forces operation of the boiler at the parameters
P5, with the ventilator (if present) in V5. Any corrections to the loading/smoke ventilation percentage must be read. This state lasts 20
minutes, the countdown is displayed on the panel. During this interval, the system ignores any thermostat/puffer/room set point/ set
point H
0 values, only the safety shut-down at 85°C remains active. At any time, the technician may interrupt this phase by pressing the
2
on/off switch quickly.
< Chimney Sweep >
8
Use key 5 to go to the settings menu and select the CHIMNEY SWEEP option. Confirm with key 5 and then with keys "b" (arrows) you can
activate or deactivate (the default option is OFF) the function. Key 5 is used to confirm, while key 8 is used to go back to the main screen.
Setting the temperature SETPOINT value
ON
10:29
Eco Mode on
By touching the display on the right-hand side, i.e. near keys 4/5, you can set the various temperature setpoint values depending on the
kind of system configuration chosen.
Technical Dept. - All rights reserved - Reproduction is prohibited
O
5
MENU
6/7
< Chimney Sweep >
On
8
20°
50°
70°
b
5
ROOM TEMPERATURE
WINTER
SUMMER
HEATING
PUMP
MAX POWER
SANITARY
TEMPERATURE
47 47