SM-E4B SERIES, WSM
Continuity across Regulator's Terminals
1. Measure with a circuit tester according to the list below.
NOTE
• For this test, use only Analog Meter and do not use a high
voltage tester such as a M Ω meter.
• This check sheet shows the results of the test conducted
by using the "Sanwa-made tester SP-10 and SP-15D"
(Analog Meter).
• Use of other testers than those above may show different
measured results. Ω shall be used as the unit for the
measuring range.
• The judgement should be as below table.
"ON" if the indicator moves, otherwise "OFF".
Check Table (
: ON,
: OFF)
Blue
Blue
Code
Black
colors
Blue
(Tester
Green
Termin
Yellow
al)
Red
(1) Blue
(2) Black
(3) Blue
Regulating Voltage
1. Complete the charging circuit with a fully charged battery and
operate the dynamo at the specified speed.
2. Measure the output voltage with a volt meter.
3. If the measurement is not within the specified values, replace
the dynamo.
Regulating output
Factory specification
voltage
1-S27
Code colors (Tester + Terminal)
Black
Blue
Green
Yellow
(4) Green
(5) Yellow
(6) Red
9Y1210785ENS0020US0
14 to 15 V at
-1
5200 min
9Y1210785ENS0021US0