4.
Condominium/free exit loop (Dipswitch 4 On)
When condominium/free exit loop is activated on the unit, the unit will not respond to an
transmit
ter or manual push button while in its opening cycle or open position. When the
gate is on the open limit the unit will automatically wait the pre-programmed auto close
time and then close (even if auto close function is not selected i.e. dipswitch 3 is off).When
the gate is in its
will stop and open. Auto close cannot be over ridden in condominium mode. If main power
fails, the motor will still operate until battery reaches 20 volt. Gate will th
Change to manual by overriding the motor by the override lever. When the main power
comes on again, lock in the override lever and the motor will function as normal.
5.
P.I.R.A.C (Passive Infra Red Access Control) (Dipswitch 5 On)
With P.I.R.A.C mode activated, if the gate is in its opening cycle and the IR beam is
activated and released the gate will stop and close immediately. When the gate is on the
open limit the unit will not automatically close unless auto close has been selected.
6.
Slowdown (Dipswitch 6)
With dipswitch selected ON, the gate will have a long close and open ramp down distance,
and with the dipswitch OFF, a short ramp down distance.
NO
TE -
(For any gate exceeding 3 meters width, the long ramp down is recommen
closing cycle and the transmitter or manual push button is pressed the gate
10
y
en remain open.
ded).