Roland SP-300 Service Manual Book page 216

Hide thumbs Also See for SP-300:
Table of Contents

Advertisement

4 Adjustment
[BIDIRECTION ADJUSTMENT]
Select [BI-DIR.DEFAULT TEST PRINT] in the [HEAD
21
ADJUST] menu and press the [ENTER] key.
4
Following TEST PATTERN will be printed.
22
Find the position where the upper block matches the lower block and check the number.
In case of having problem deciding the number, the number between the 2 numbers can be selected.
The number with
H2
H1
DT3
H2
H1
DT1
Select [DT1] and [DT3] and in the [BI-DIR. DEFAULT]
23
menu and enter the parameters checked at 22
with [
] and [
Press the [ENTER] key to save the settings.
Parameters can be entered
with an increment of 0.5.
4-24
is the current setting.
0
+9
+10
+11
+12
0
+9
+10
+11
+12
] keys.
+13
+14
+15
+16
+17
+18 +19 +20 +21
+13
+14
+15
+16
+17
+18 +19 +20 +21
HEAD ADJUST
BI-DIR.DEFAULT
SERVICE MENU
HEAD ADJUST
[ ]
HEAD ADJUST
BI-DIR.DEFAULT
[ ]
BI-DIR.DEFAULT
TEST PRINT
[ ]
+40
+40
BI-DIR.DEFAULT
TEST PRINT
BI-DIR.DEFAULT
H1 H2
ADJUST DT1
2
BI-DIR.DEFAULT
H1 H2
ADJUST DT3
2
3
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents