Un iq Ue ser v i c e P r o ce d U re s
77

EGR Valve Removal

• Removing the EGR valve must be performed using the
proper EGR valve removal tool.
• This tool is comprised of numerous pieces that
must be put together around the EGR valve.
• Once the removal tool is assembled on the valve,
the valve can be slowly pulled from its housing.
• Tool # 303-1267
NOTE: Pay close attention that the removal tool is
installed and used correctly while removing the valve
or damage can occur to the EGR valve and/or tool.

Crossover Tube Seal Removal

• Crossover tube seal removal requires the use of special
service tools; slide hammer, seal removal tools.
• There is a different size removal tool for
each opening of the crossover tube.
• Tool # 303-1264

Crossover Tube Seal Installation

• When installing new seals into the turbocharger crossover
tube, always use the appropriate installation tools.
• The seals for each passage are two (2) different
sizes. Make sure you use the correct sized
seal installation tool for each sized seal.
NOTE: Make sure you have the crossover tube mounted
securely to assure proper seal installation.