SLEEP MODE (USED ON ALL MODELS WITHOUT A CIRCULATION PUMP)
The Sleep Mode operation is a feature that minimizes pump operation during quiet evening hours. For example, if Filter Cycle 1 (F1) is set to
activate at 8:00 a.m., by default, Filter Cycle 2 (F2) will activate at 8:00 p.m. (12 hours later). During 8:00 p.m. to 8:00 a.m., if the spa should call for
heat, the pump and heater will activate to heat the spa under normal temperature demand. However, when in Sleep Mode, should the spa call for
heat, the pump and heater will be suspended after Filter Cycle 2 (F2) until the activation of Filter Cycle 1 (F1), at 8:00 a.m. to minimize pump activation
during quiet evening hours.
Important: Power-up of the spa starts the F1 sequence. In order for the sleep mode to work in the evening hours, the spa must be powered up in
the early morning hours. The Sleep Mode will always be active the 6-12 hours between the end of (F2) and the beginning of (F1) depending on how
the filter cycle program is set.
Note: If temperature drops below 80º F (27º C), heater will automatically activate to prevent spa from freezing.
To activate Sleep Mode feature:
A. Press the SET button until the TOOLS menu is displayed.
B. Press the TEMP   b utton to enter the TOOLS submenus.
C. Press the SET button until ECON is displayed on the screen.
D. Press the TEMP   b utton to activate Sleep Mode. Moon & Stars icon will apear in the display of the control panel, indicating this feature has
been activated.
To deactivate this feature, simply repeat steps A-C then press the TEMP  button.
FILTER CYCLES (USED ON ALL MODELS WITHOUT A CIRCULATION PUMP)
When the spa is first powered up, the automatic filter cycle will wait 10 minutes before starting. Your spa will automatically turn the first filter cycle on
for 60 minutes on low speed. The second filter cycle will activate for 30 minutes, 12 hours later. The filter cycle icon, F1 or F2 will be displayed in the
control panel during the filter cycle.
NOTE: The optional FRESHWATER III ozone system only works during the filter cycle.
To modify the length of either filter cycle:
A. Press the SET button until the TOOLS menu is displayed.
B. Press the TEMP   b utton to enter the TOOLS submenus.
C. Press the SET button until FILT1 or FILT2 is displayed on the screen.
D. Press the TEMP   b utton to enter FILT1 or FILT2. F1 or F2 icon will flash.
E. Using the TEMP  or the TEMP  button, adjust the desired filter cycle time, from 0 to 6 hours.
The filter cycle will activate the jet pump on low speed for the entire cycle. When activated, the filter cycle icon on the display is turned on. If the
temperature exceeds the set point by three degrees F for more than three hours, the system will cancel the filter cycle for the remaining filter cycle
time. Should the temperature cool down to 1.5 degrees F (1 degree C) below the set point before the end of the cycle, the cycle will resume for the
rest of the time. Should you use the spa during the filter cycle by placing the jet pump on high speed, the Filter icon and Jets icon will be on. Once
the jet pump has been shut off, a ten minute tranquil mode begins (Filter & Jet icons are off during tranquil mode while F1 or F2 remain lit). The
Filter and Jet icons will come back on once the tranquil mode ends if the filter cycle timer is still on.

AUDIO MENU (OPTIONAL)

The following applies to spas that have an optional wireless audio system installed:
When the wireless audio system has been installed on the spa, the control panel can be used to control the audio system. The following information
demonstrates how to navigate the music menu by using the spa's control panel.
AUDIO MENU
Once the music system is installed, an AUDIO menu will be accessible on the control panel screen.
To access the menu, press the SET button on the control panel until AUDIO is displayed.
BASIC CONTROL PANEL OPERATION
To enter into a sub-menu, or to adjust the current function displayed, use the TEMP ▲ or TEMP ▼ buttons.
To move to the next menu use the SET button.
To exit from any sub-menu, press SET as many times as necessary until EXIT is displayed then press TEMP▲ button to exit that sub-menu.