Electrical Data - Gree TERRA09HP230V1A Technical Product Manual

Hide thumbs Also See for TERRA09HP230V1A:
Table of Contents

Advertisement

ELECTRICAL DATA

Outdoor Unit
Model Numbers
TERRA09HP230V1AO
TERRA12HP230V1AO
TERRA18HP230V1AO
TERRA24HP230V1AO
Outdoor Unit
Model Numbers
TERRA09HP230V1AO
TERRA12HP230V1AO
TERRA18HP230V1AO
TERRA24HP230V1AO
Model Numbers
TERRA09HP230V1AO
TERRA12HP230V1AO
TERRA18HP230V1AO
TERRA24HP230V1AO
Legend:
RLA – Rated Load Amps LA – Full Load AmpsLRA – Locked Rotor AmpsMCA – Min. Circuit Amps
Rated Power Supply
Voltage Range
(volt-phase-hz)
208/230v-1ph-60hz
208/230v-1ph-60hz
208/230v-1ph-60hz
208/230v-1ph-60hz
Rated Input Current (amps)
Cooling
Heating
5.7
6.0
7.4
8.5
Compressor
RLA
LRA
(amps)
(amps)
3.2
13.8
3.2
13.8
8.4
27.0
12.0
40.0
© 2014 Gree Electric Appliance, Inc.
Rated Input Power (watts)
(volts)
Cooling
187-253
600
187-253
882
187-253
1500
187-253
1850
Min. Circuit
Amp. (MCA)
7.0
10
7.5
10
7.8
15
10.3
20
Outdoor Fan
RLA
Input Power
(amps)
(Watts)
0.2
40
0.2
40
0.3
60
0.4
90
Heating
650
960
1580
2250
Max Fuse
Size (Amps)
15
15
20
30
Indoor Fan
RLA
Input Power
(amps)
(Watts)
0.1
10
0.1
10
0.1
25
0.3
70
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terra18hp230v1aTerra24hp230v1aTerra12hp230v1a

Table of Contents