Turning On The Control Panel; Network Connection Indicator; Record Alarm Message; Settings Inquiry By Sms - Response Electronics miGuard G5 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Turning on the Control Panel

Plug the Power Adapter into the Power Adapter Socket underneath the Control Panel
battery cover - then slide the power switch to `On' (see diagram on page 8).
GSM Network Connection Indicator
After switching on the system, the network indicator flashes once every second. This
indicates that the Control Panel is searching for a network. When connected to a network
the LED indicator will flash once every two seconds.
Note:
If the LED indicator continues to flash once every second, the Control Panel has not
connected to a network.
Test Mode
The alarm system can be put into Test Mode. This will cause the Panel to beep three
times and light up the zone numbers (zones 1-9 only) when a Sensor is triggered,
instead of activating the siren.
To enter Test Mode press the
button on the Control Panel three times until the system
beeps once. After 10 minutes the system will automatically exit Test Mode. It is also
possible to exit Test Mode by pressing the

Record Alarm Message

When the alarm is activated the Control Panel will call the pre-programmed phone
numbers and play a message. This message can be recorded by pressing the
button, then the disarm code (default 1234), press the
the
button, you then have 10 seconds to record a message.

Settings Inquiry by SMS

The settings of the alarm system can be changed by sending an SMS text from your
mobile phone. You can request a list of all available SMS commands. The complete
menu consists of three parts which can be requested by sending one, two or three
9
button.
button again and finally press
'0' Disarm
'1' Arm
'2' Home mode
'3' Two-way talk
'4' Call-back voice memo
'00' Settings inquiry
'??' Store phone and SMS No.
'5' Store alarm phone No.
'6' Store alarm SMS No.
'7' Store SMS No. for RFID tags
'8' Store speed dial phone No.
'???' System setups
'91~99' Zone name
'10' RFID tags SMS notice
'11' Entry and exit delay time
'12' Siren volume and ringing time
'13' Disarm password
'14' Single zone delay time
?
??
???
10