Electra DNC series Service Manual page 89

Table of Contents

Advertisement

CONTROL SYSTEM
only controlled by the 3 min Min OFF time and 1 min Min ON
time.
4. In Dry Mode, IFAN is LOW when COMP is ON, and is OFF
when COMP is OFF.
5. Pumps are operating as indicated in Sect. 7.3, 7.4, and 7.5.
6. HEs are always OFF in Dry Mode.
6.2.
Dry, SH or RH group excluding P2000 model
Mode: Dry
Temp: Selected desired temp.
Fan:
Low (automatically selected by software)
Timer: Any
I FEEL:
Any
Control function
Reduce room humidity with minimum Temp. fluctuations by operating
in Cool Mode with low speed IFAN and HE.
o
(RT - SPT) [
c]
+2
+1
0
10
-1
-2
LOW
IFAN
OFF
ON
COMP
OFF
& OFAN
ON
HE1
OFF
ON
HE2
OFF
ON
RV
OFF
Notes :
1) HP and Defrost protections are the same as in Cool Mode.
8-22
20
30
Revision Y05-01
CONTENT
40
50
Time [min]
Service Manual - DNC Series