CONTROL SYSTEM
Auto Cooling or Heating RH Group
Mode: Auto
Temp: Selected desired temperature
Fan:
Any
Timer: Any
I Feel: On or Off
Control function
Maintains room temp at desired level by selecting between Cooling or
Heating Modes.
o
(RT - SPT) [
c]
+3
+2
+1
0
-1
-2
-3
Auto Heat Mode
ON
COMP
OFF
& OFAN
ON
HE1
OFF
ON
HE2
OFF
H/M/L
L
IFAN
OFF
30 sec
(1)
OFF
RV
Notes:
1)
Refer to Sect. 4.0.3.c for the details of IFAN operation.
2)
Refer to Sect 5.0.5 for the minimum mode-change delay from
COMP/HEs OFF.
8-20
Auto Cool Mode
> 3 min
(2)