1. The ICT is also monitored during Cool and Dry mode, in case
the RV control circuit is faulty. Whenever ICT reaches 70
which indicates a high pressure in the indoor coil, the COMP
will be forced off automatically. The COMP can be turned on
again only after the ICT is under 70
COMP ON delay time. The OPER LED will not blink in this
case.
7.2.
Heating Mode Protections
7.2.1. Outdoor coil Deicing (excluding RH Group)
Mode: Heating, Auto (at heating)
Temp: Selected desired Temp
Fan:
Any
Timer: Any
I FEEL:
Control function
Protects the Outdoor coil from ice formation by controlling COMP &
RV operation.
7.2.1.2 Deicing procedure
Service Manual - DNC Series
o
c again and after the 3 min
Any