CONTROL SYSTEM
CONFIGURATION OF THE APPLIANCE
SETTING SWITCH STATUS
SW. NO. 1
SW. NO. 2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
_
_
_
_
_
_
_
_
RESET OPERATION - Press at the same time the 4 buttons :"CLEAR ", "SET" ,
"HR +", "HR -"
LEGEND:
SW1, SW2 - SELECTION OF RC/ST
SW3 - SELECTION OF TEMP. DISPLAY °C or °F IN RC3 OR SWING FUNCTION IN RC4.
SW4 - SELECTION OF TIME DISPLAY 12H AM/PM or 24H IN RC3 0R ILLUMINATION FUNCTION IN RC4.
OFF = 0
ON =1
NOTE: After setting the dip switches perform reset operation..
8-4
REMOTE CONTROL DIP SWITCH SETTING
SW. NO. 3
SW. NO.4
_
_
_
_
_
_
_
_
TEMP. DISPLAY IN °C DEGREES
OFF
_
TEMP. DISPLAY IN °F DEGREES
ON
_
_
OFF
_
ON
for 5 seconds
Revision Y05-01
CONTENT
DEFINITION
RC3
RC-ALL MODES OF OPERATION
STD-COOL, FAN, DRY, ACTIVE
HEAT-COOL, FAN, DRY, ACTIVE
AUTO FAN (AF)
TIMER & CLOCK 12 H AM, PM
TIMER & CLOCK 24 H
Service Manual - DNC Series
RC4
VERTICAL SWING ONLY
HORIZONTAL & VERTICAL SWING
FUNCTIONS TOGETHER
DISABLE LCD &
KEY ILLUMINATION
ENABLE LCD &
KEY ILLUMINATION