Scan Data Transmission Format (MS-XX07)

To change the Scan Data Transmission Format, scan the Scan Options bar code below,
then select one of four options:
Data As Is
<DATA> <SUFFIX>
<PREFIX> <DATA>
<PREFIX> <DATA> <SUFFIX>
After making a selection, scan the Enter bar code on page 9-113. To change the selection
or to cancel an incorrect entry, scan the Data Format Cancel bar code on page 9-113.
To add a carriage return/enter after each bar code scanned, scan the following bar codes
in order:
1. <SCAN OPTIONS>
2. <DATA> <SUFFIX>
3. Enter (on page 9-113).
9-112
Scan Options
*Data As Is