MS-120X and MS-220X Integration Guide
CLSI Editing
Parameter # 36h
When enabled, this parameter strips the start and stop characters and inserts a space after
the first, fifth, and tenth characters of a 14-character Codabar symbol.
Note: Symbol length does not include start and stop characters.
9-86
Enable CLSI Editing