Advertisement

Quick Links

Special
Operating
Instructions
for
M2004-I418
73-39696-418
Revision A - February 2004

Advertisement

Table of Contents
loading

Summary of Contents for Symbol M2004-I418

  • Page 1 Special Operating Instructions M2004-I418 73-39696-418 Revision A - February 2004...
  • Page 2: Table Of Contents

    NRC Mode Plural Stage Select....10 Plural Stage Inter-Decode Wait Time..11 Plural Stage Decode Inhibit Timeout Be- tween Full Stage Decodes ......11 Plural Stage Same Single Symbol Timeout ............... 12 Plural Stage Row Data Transmission Format Options ..........13 Row Prefix/Suffix Values......18...
  • Page 3: Features

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Features The M2004-I418 differs from the standard in the following ways: • Plural Stage bar code decoding is support- • Custom default parameter settings are im- plemented. • Supplemental Recognition Characters are supported.
  • Page 4: Custom Default Parameter Settings

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 details regarding the formatting of the row data. Custom Default Parameter Settings* Parameter Default Setting Plural Stage Mode Use Recognition Codes (RC Mode) Decode 2-Stage bar codes Disabled (Applies to RC Mode)
  • Page 5 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Parameter Default Setting All Row Recognition Codes None (i.e., Not Set) All Position Values 0 (i.e., Not Set) All Relative Start Position Set- From Left tings Decode Inhibit Timer 500ms Inter-Decode Wait Time...
  • Page 6: Decode 2-Stage Bar Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Decode 2-Stage Bar Codes When Decode 2-Stage Bar Codes is enabled, the following parameter values are set: 2 Stage, Row 1, Code 1 Characters>:97 2 Stage, Row 1, Code 1 position value> for first character "9":01...
  • Page 7: Plural Stage Mode Select Bar Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage Mode Select Bar Codes Scan one of the following bar codes to set the plural stage mode. In RC mode the scanner attempts to match scanned bar codes with stored recognition codes in order to decode and transmit plural stage bar codes.
  • Page 8: Rc Mode Plural Stage Enable/Disable Bar Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 RC Mode Plural Stage Enable/Disable Bar Codes Scan the bar code(s) below that represents the desired choice(s) for enabling and disabling Plural Stage decoding while in RC Mode. Enable 2-Stage Decoding...
  • Page 9 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Enable 4-Stage Decoding Disable 4-Stage Decoding...
  • Page 10: Nrc Mode Plural Stage Select

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 NRC Mode Plural Stage Select When the Plural Stage Mode is set to NRC Mode, scan the bar code below that corresponds to the number of unique barcodes the scanner should attempt to decode before transmitting.
  • Page 11: Plural Stage Inter-Decode Wait Time

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage Inter-Decode Wait Time When a bar code from a plural stage set is decoded, this parameter sets the amount of time within which an attempt is made to decode the next plural stage bar code within the set.
  • Page 12: Plural Stage Same Single Symbol Timeout

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage Same Single Symbol Timeout This parameter sets the time the scanner waits after a plural stage bar code is decoded to accept decodes of any of the single bar codes making up this plural stage bar code.
  • Page 13: Plural Stage Row Data Transmission Format Options

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage Row Data Transmission Format Options Scan the bar code(s) that corresponds to the desired data transmission format for each row. First Row Format Options <ROW 1 DATA> <ROW 1 PREFIX><ROW 1 DATA>...
  • Page 14 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Second Row Format Options <ROW 2 DATA> <ROW 2 PREFIX><ROW 2 DATA> <ROW 2 DATA><ROW 2 SUFFIX> <ROW 2 PREFIX><ROW 2 DATA> <ROW 2 SUFFIX>...
  • Page 15 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Third Row Format Options <ROW 3 DATA> <ROW 3 PREFIX><ROW 3 DATA> <ROW 3 DATA><ROW 3 SUFFIX> <ROW 3 PREFIX><ROW 3 DATA> <ROW 3 SUFFIX>...
  • Page 16 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Fourth Row Format Options <ROW 4 DATA> <ROW 4 PREFIX><ROW 4 DATA> <ROW 4 DATA><ROW 4 SUFFIX> <ROW 4 PREFIX><ROW 4 DATA> <ROW 4 SUFFIX>...
  • Page 17 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Fifth Row Format Options <ROW 5 DATA> <ROW 5 PREFIX><ROW 5 DATA> <ROW 5 DATA><ROW 5 SUFFIX> <ROW 5 PREFIX><ROW 5 DATA> <ROW 5 SUFFIX>...
  • Page 18: Row Prefix/Suffix Values

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row Prefix/Suffix Values To set the prefix/suffix values for plural stage row data, scan the corresponding bar code followed by four numeric bar codes, starting page 39. See the ASCII Equivalent Tables ™...
  • Page 19 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 ROW 3 PREFIX ROW 3 SUFFIX ROW 4 PREFIX ROW 4 SUFFIX...
  • Page 20: Transmit Plural Stage Row Recognition Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 ROW 5 PREFIX ROW 5 SUFFIX Transmit Plural Stage Row Recognition Codes Scan one of the following bar codes to enable or disable the transmission of recognition code characters. Transmit Recognition Code...
  • Page 21: Plural Stage Adf Rule

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage ADF Rule A new ADF criteria and action allow formatting of plural stage data. When any plural stage bar code is read (criteria is “When Plural Stage Scan”), the data is sent according to the specification (action is “Send...
  • Page 22 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 criteria) without erasing all rules to return to the default rule. To change the Scan Data Transmission ™ Format parameter from the Cyclone M2000 Series Product Reference Guide, scan the “Normal Scan Data Transmission Option” bar code below instead of the “Scan Options”...
  • Page 23: Plural Stage Row Recognition Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Plural Stage Row Recognition Codes Up to two different recognition codes can be programmed for each row within each type of plural stage bar code (2-Stage, 3-Stage, or 4- Stage). A recognition code consists of from 1 to 3 ASCII characters.
  • Page 24 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 self. The first bar code scanned repre- sents the most significant digit. For example, to enter a position value of 10, scan 1, then 0. Note: All row 1 recognition codes (for...
  • Page 25 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 2-Stage Recognition Codes Row 1 Codes - First Code 2-Stage, Row 1, Code 1 Characters 2-Stage, Row 1, Code 1 Position Values Row 1 Codes - Second Code 2-Stage, Row 1, Code 2 Characters...
  • Page 26 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 2 Codes - First Code 2-Stage, Row 2, Code 1 Characters 2-Stage, Row 2, Code 1 Position Values Row 2 Codes - Second Code 2-Stage, Row 2, Code 2 Characters...
  • Page 27 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 3-Stage Recognition Codes Row 1 Codes - First Code 3-Stage, Row 1, Code 1 Characters 3-Stage, Row 1, Code 1 Position Values Row 1 Codes - Second Code 3-Stage, Row 1, Code 2 Characters...
  • Page 28 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 2 Codes - First Code 3-Stage, Row 2, Code 1 Characters 3-Stage, Row 2, Code 1 Position Values Row 2 Codes - Second Code 3-Stage, Row 2, Code 2 Characters...
  • Page 29 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 3 Codes - First Code 3-Stage, Row 3, Code 1 Characters 3-Stage, Row 3, Code 1 Position Values Row 3 Codes - Second Code 3-Stage, Row 3, Code 2 Characters...
  • Page 30 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 4-Stage Recognition Codes Row 1 Codes - First Code 4-Stage, Row 1, Code 1 Characters 4-Stage, Row 1, Code 1 Position Values Row 1 Codes - Second Code 4-Stage, Row 1, Code 2 Characters...
  • Page 31 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 2 Codes - First Code 4-Stage, Row 2, Code 1 Characters 4-Stage, Row 2, Code 1 Position Values Row 2 Codes - Second Code 4-Stage, Row 2, Code 2 Characters...
  • Page 32 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 3 Codes - First Code 4-Stage, Row 3, Code 1 Characters 4-Stage, Row 3, Code 1 Position Values Row 3 Codes - Second Code 4-Stage, Row 3, Code 2 Characters...
  • Page 33 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Row 4 Codes - First Code 4-Stage, Row 4, Code 1 Characters 4-Stage, Row 4, Code 1 Position Values Row 4 Codes - Second Code 4-Stage, Row 4, Code 2 Characters...
  • Page 34: Clearing Recognition Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Clearing Recognition Codes Scan one of the following bar codes to clear all recognition codes, clear only 2-stage codes, clear only 3-stage codes, or clear only 4-stage codes. To clear a single recognition code, scan the...
  • Page 35: Recognition Characters Done

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Recognition Characters Done Scan the bar code below when you have finished entering recognition code characters. Recognition Chars Done Position Value Placement Scan a bar code below to select relative to the left side or relative to the right side when entering a position value.
  • Page 36: Enable/Disable Supplemental Recognition Characters

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Enable/Disable Supplemental Recognition Characters To enable or disable the Supplemental Recognition Characters (SRC) scan one of the following bar codes. Enable SRC Disable SRC Supplemental Recognition Characters The Supplemental Recognition Characters...
  • Page 37 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 To set a Supplemental Recognition Character: 1. Scan the “Set SRC” bar code below to select new supplemental recognition characters. Set SRC 2. Scan up to three alphanumeric bar codes from the Cyclone M2000 Se- ries Product Reference Guide.
  • Page 38: Agc Control

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 AGC Control AGC Control is used by the M2004-I400 standard product to prevent mis-decodes and double decodes when in Omni-directional and Semi-Omni-directional modes. In order to decode "Low Density" barcodes in Omni and...
  • Page 39: Numeric Keypad Bar Codes

    M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Numeric Keypad Bar Codes...
  • Page 40 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004...
  • Page 41 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004 Cancel...
  • Page 42 M2004-I418 Special Operating Instructions (73-39696-418) Revision A: February 2004...

Table of Contents