LT 1804 Product Reference Guide: Programming the LT 1804

Transmit "No Decode" Character

This feature gives you the option to transmit "NR" when a symbol does not
decode. Prefixes and suffixes enabled will be appended around this character.
Note: This option is available in Triggered Mode only.

Stop Bit Select

The stop bit(s) at the end of each transmitted character marks the end of
transmission of one character and prepares the receiving device for the next
character in the serial data stream. The number of stop bits (one or two)
selected depends on the number the receiving terminal is programmed to
accommodate. Set the number of stop bits to match host device requirements.

Scan Data Transmission Format (Synapse Hosts Only)

This parameter formats the data for transmission. Options are:
None (Data As Is)
Prefix/Data
Prefix/Data/Suffix
Data/Suffix.
Prefix (RS-232)
The scanner will add one of the following start-of-text characters to
transmitted data.
None
Start-of-text <STX>
One user-defined prefix (can be any ASCII character).
Suffix (RS-232)
Select one or two end-of-text characters to be added to transmitted data:
None
CR (Carriage Return) - Returns the cursor to the same position on the line
after each decode.
LF (Line Feed) - Moves the cursor down a line after each decode.
4-10