12.
Engaging solenoid
05.04
Requirement
With the trimming device swichted on, the field core must still be 1 mm before its lower
stop.
Fig. 12 - 21
Bring the needle bar to BDC and activate the tripping lever by hand.
Push solenoid housing 1 ( screw 2 ) up as far as possible and then move it in accordance
with the requirement.
Lift the tripping lever out of the control cam by hand.
1
2
Adjustment
12 - 23