Adjustment
12.
Radial position of the tripping lever
05.03
12 - 22
Requirement
With the tripping lever 3 in resting position, there must be a clearance of 0.3 mm between
its roller and the circumference of the control cam 4.
Fig. 12 - 20
Bring the needle bar to BDC.
Move solenoid carrier 1 ( nuts of screws 2 ) in accordance with the requirement.
4
3
2
1