13
Engaging solenoid
.05.04
Rule
There should be a clearance of 0.3 mm between the engaging lever 2 and the pawl 3 in
the needle rise position and when the engaging solenoid 5 is activated.
2
Fig. 13 - 22
O Move the machine to the needle rise position by turning the handwheel.
O Loosen the screw 1 until the engaging solenoid is hard to push.
O Activate the engaging lever 2 by hand so that the pawl 3 drops into place.
O Press the magnet armature 4 into the magnet housing 5 up to the stop and adjust the
magnet housing together with the magnet armature according to the rule.
O Tighten the screw 1 in this position.
3
4
5
1
5
Adjustment
27