11

Engaging solenoid

.05.04
Requirement
With the needle bar at b.d.c. and solenoid core 1 fully operated there must be a clearance
of approx. 0.5 mm between locking pawl 4 and fixing collar 5.
Fig. 11 - 14
● Set the needle bar at b.d.c.
● Push solenoid core 1 fully in.
● Position solenoid housing 2 (screw 3) according to Requirement
3
2
1
Adjustment
5
0.5 mm
4
11 - 15