System Unit Specifications; Server Chassis Specifications - Hitachi Compute Blade 500 Series System Overview Manual

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

System Unit Specifications

This section describes specifications for the system unit.

Server Chassis Specifications

The following table provides the server chassis specifications.
Enclosure
Number of modules
that can be installed
External dimensions (W x D x H: mm)/number of units according to the EIA
standard
Mass
Power source
Environmental
requirements
2-2
Table 2-1 Server Chassis Specifications
Items
Server blades
Management modules
Switch
modules
Switch bays #0 and #1
Switch bays #2 and #3
Power supply
Power supply bays
modules
Redundant
configuration
Power input
Fan modules
Input voltage (Frequency)
Power consumption (Maximum)
Temperature
Specification
Hitachi Compute Blade 500 Series System Overview Guide
Rack mount type 6 U
Up to 8 blades
Up to 2 modules
Up to 4 modules
Up to 2 modules
Same type of modules
must be installed.
FC switch module is not
available.
Up to 2 modules
Same type of modules
must be installed.
Up to 4 units
Rated at 100
1+1 or 2+1 or 2+2 or 3+1
Vac
Rated at 200
1+1 or 2+1 or 2+2 or 3+1
Vac
100 Vac: 3597 W / 200
Vac: 5140 W
6 modules as standard (N
+M modules
configuration)
447 x 791 x 262 / 6 U
Maximum: 130 kg
(with all modules
installed; including rack
rails)
Single Phase AC
100-120 V / 200-240 V
(50-60 Hz)
1
4678 W
5 to 40°C [Non-operating:
-10 to 43 °C]
Specifications
3

Hide quick links:

Advertisement

Table of Contents